{"id":80605,"date":"2024-10-17T18:46:02","date_gmt":"2024-10-17T18:46:02","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-12-44-2000\/"},"modified":"2024-10-24T19:44:05","modified_gmt":"2024-10-24T19:44:05","slug":"ieee-c57-12-44-2000","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-12-44-2000\/","title":{"rendered":"IEEE C57.12.44 2000"},"content":{"rendered":"
Revision Standard – Inactive – Superseded. Superseded by IEEE Std C57.12.44-2005 The performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment is established as a basis for use in this standard. Certain electrical, dimensional, and mechanical characteristics are described; and certain safety features of three-phase, 60 Hz, low-voltage (600 V and below) network protectors are taken into consideration. This equipment is used for automatically connecting and disconnecting a network transformer from a secondary spot or grid network.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Introduction Participants <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | \tCONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1. Overview 1.1 Scope 1.2 Purpose 1.3 Word usage 2. References <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 3. Definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4. Service conditions 4.1 Usual service conditions 4.2 Unusual service conditions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5. Design tests 5.1 Continuous current thermal test <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.2 Electrical tests <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3 Mechanical endurance test 6. Production tests <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.1 Operational tests <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.2 Dielectric tests <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.3 Insulation resistance tests <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.4 Current path resistance tests 6.5 Mechanical tests <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7. Relay characteristics 7.1 General 7.2 Closing characteristics 7.3 Tripping characteristics 7.4 Closing adjustment <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7.5 Tripping adjustment <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8. Fuses and fuse mountings 8.1 Fuse provisions <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.2 Functional performance specifications 8.3 Fuse types <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 9. Rating requirements 9.1 Nameplates 9.2 Interrupting rating 9.3 AC voltage ratings 9.4 Dielectric test voltage 9.5 Control voltage <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 9.6 Closing voltage 9.7 Tripping currents <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 10. Mechanical performance specifications 10.1 Submersible type 10.2 Nonsubmersible type 10.3 Open frame type <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 10.4 Mounting application 10.5 General requirements <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 10.6 Finish 11. Other requirements 11.1 Submersible enclosure 11.2 Nonsubmersible enclosure <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 11.3 Open frame enclosure 11.4 Mounting configurations 11.5 Network-side terminations <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Annex A\u2014Classification of insulating materials <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Annex B\u2014Network fuse application <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Annex C\u2014Pumping <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex D\u2014The unprotected zone in network protectors <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Annex E\u2014Contact surface oxidation <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Annex F\u2014Reverse current sensitivity <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Annex G\u2014Network protector enclosures <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Standard Requirements for Secondary Network Protectors<\/b><\/p>\n |