{"id":75089,"date":"2024-10-17T17:02:20","date_gmt":"2024-10-17T17:02:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d888-2012\/"},"modified":"2024-10-24T19:19:07","modified_gmt":"2024-10-24T19:19:07","slug":"astm-d888-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d888-2012\/","title":{"rendered":"ASTM-D888 2012"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover the determination of dissolved oxygen in water. Three test methods are given as follows:<\/p>\n

1.2 The precision of Test Methods A and B was carried out using a saturated sample of reagent water. It is the user’s responsibility to ensure the validity of the test methods for waters of untested matrices.<\/p>\n

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Note 17.<\/span><\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Significance and Use
Purity of Reagents <\/td>\n<\/tr>\n
2<\/td>\nSampling
Preservation of Samples
Scope
Interferences
Apparatus
Reagents <\/td>\n<\/tr>\n
3<\/td>\nProcedure <\/td>\n<\/tr>\n
4<\/td>\nCalculation
Precision and Bias
Quality Control <\/td>\n<\/tr>\n
5<\/td>\nScope
Summary of Test Method
Interferences <\/td>\n<\/tr>\n
6<\/td>\nApparatus
Apparatus Standardization <\/td>\n<\/tr>\n
7<\/td>\nSampling
Procedure <\/td>\n<\/tr>\n
8<\/td>\nCalculation
Precision and Bias
Quality Control
Scope <\/td>\n<\/tr>\n
9<\/td>\nSummary of Test Method
Apparatus
Calibration and Calibration Verification
FIG. 1 <\/td>\n<\/tr>\n
10<\/td>\nPrecision and Bias
Quality Control
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n
11<\/td>\nKeywords
X1. OXYGEN SATURATION VALUES
X1.1 Oxygen Saturation Values in Water and Elevations
X1.2 Oxygen Saturation Values in Water and Salt Waters
X2. TWO-POINT CALIBRATION ZERO POINT STEPS
X2.1
X2.2
X2.3
TABLE X1.1
TABLE X1.2 <\/td>\n<\/tr>\n
12<\/td>\nTABLE X2.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D888-12 Standard Test Methods for Dissolved Oxygen in Water<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2012<\/td>\n12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":75090,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[216,2637],"product_tag":[],"class_list":{"0":"post-75089","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-060-50","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/75089","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/75090"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=75089"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=75089"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=75089"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}