{"id":398105,"date":"2024-10-20T04:33:53","date_gmt":"2024-10-20T04:33:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-13-2015-2\/"},"modified":"2024-10-26T08:22:14","modified_gmt":"2024-10-26T08:22:14","slug":"ieee-c37-13-2015-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-13-2015-2\/","title":{"rendered":"IEEE C37.13-2015"},"content":{"rendered":"

Revision Standard – Active. The following enclosed low-voltage ac power circuit breakers are covered in this standard: a) stationary or drawout type of two-, three-, or four-pole construction, with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V; b) unfused or fused circuit breakers; c) manually or power operated; and d) with or without electromechanical or electronic trip devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, application, and the preferred ratings are discussed in this standard.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std C37.13-2015 Front Cover <\/td>\n<\/tr>\n
3<\/td>\nTitle page <\/td>\n<\/tr>\n
5<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
8<\/td>\nParticipants <\/td>\n<\/tr>\n
10<\/td>\nIntroduction <\/td>\n<\/tr>\n
12<\/td>\nContents <\/td>\n<\/tr>\n
14<\/td>\nImportant Notice
1. Overview
1.1 Scope <\/td>\n<\/tr>\n
15<\/td>\n1.2 Purpose
2. Normative references <\/td>\n<\/tr>\n
16<\/td>\n3. Definitions <\/td>\n<\/tr>\n
17<\/td>\n4. Service conditions
5. Ratings
5.1 General <\/td>\n<\/tr>\n
18<\/td>\n5.2 Rated maximum voltage
5.3 Rated power frequency
5.4 Rated frame size
5.5 Rated continuous current <\/td>\n<\/tr>\n
19<\/td>\n5.5.1 Preferred electronic trip system current ratings and settings
5.5.2 Preferred electromechanical trip system current ratings and settings
5.6 Rated short-circuit current
5.6.1 General <\/td>\n<\/tr>\n
20<\/td>\n5.6.2 Circuit breaker (50\u00a0Hz or 60\u00a0Hz)
5.6.3 Circuit breaker (50\/60\u00a0Hz)
5.6.4 Unfused circuit breakers <\/td>\n<\/tr>\n
21<\/td>\n5.6.5 Fused circuit breakers
5.6.5.1 Integrally and nonintegrally fused circuit breakers <\/td>\n<\/tr>\n
22<\/td>\n5.6.5.2 Nonintegrally fused circuit breakers\u2014Fuse drawout assembly
5.6.5.3 Fused circuit breaker frames <\/td>\n<\/tr>\n
23<\/td>\n5.7 Rated short-time current and short-time current duration
5.7.1 Unfused circuit breakers
5.7.2 Fused circuit breakers
5.8 Rated control voltage <\/td>\n<\/tr>\n
25<\/td>\n6. Functional components
6.1 General
6.2 Nameplate(s) <\/td>\n<\/tr>\n
26<\/td>\n6.3 Manual releases <\/td>\n<\/tr>\n
27<\/td>\n6.4 Contact position indicator
6.5 Stored energy indicator
6.6 Open-fuse trip device
6.7 Locking
6.8 Primary disconnect devices <\/td>\n<\/tr>\n
28<\/td>\n6.9 Circuit breaker ground connection
6.10 Fused drawout assembly
7. Temperature limitations and classification of insulating materials
7.1 Temperature limits
7.2 Limits of temperature rise
7.3 Classification of insulating materials
7.3.1 Flame-resistant capabilities
7.3.1.1 Insulating materials in contact with primary voltage parts <\/td>\n<\/tr>\n
29<\/td>\n7.3.1.1.1 Sheet insulating materials
7.3.1.1.2 Molded or cast insulating materials
7.3.1.2 Insulating materials not in contact with primary voltage parts
7.3.1.2.1 Polymeric materials
7.3.1.2.2 Non-polymeric materials <\/td>\n<\/tr>\n
30<\/td>\n7.3.2 Thermal capabilities
7.3.3 Tracking capabilities
8. Test procedures
8.1 Retest schedule
8.2 Test values
8.2.1 General
8.2.2 Dielectric withstand test voltage values <\/td>\n<\/tr>\n
31<\/td>\n8.3 Overload and endurance <\/td>\n<\/tr>\n
32<\/td>\nAnnex A (informative) Application guide <\/td>\n<\/tr>\n
45<\/td>\nAnnex B (informative) Bibliography <\/td>\n<\/tr>\n
46<\/td>\nBack Cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2015<\/td>\n46<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":398108,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-398105","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/398105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/398108"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=398105"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=398105"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=398105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}