{"id":382425,"date":"2024-10-20T03:16:05","date_gmt":"2024-10-20T03:16:05","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/smacna-hvacductconstruction-4thed-2021\/"},"modified":"2024-10-26T05:56:44","modified_gmt":"2024-10-26T05:56:44","slug":"smacna-hvacductconstruction-4thed-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/smacna\/smacna-hvacductconstruction-4thed-2021\/","title":{"rendered":"SMACNA HVACDuctConstruction 4thed 2021"},"content":{"rendered":"
Building on a history of duct construction standards nearly 100 years old, the flagship SMACNA HVAC Duct Construction Standard \u2013 Metal & Flexible 4th edition represents the state of the art in the sheet metal duct fabrication and installation requirements. Significant changes for the 4th edition include; flat oval tables for positive\/negative pressure applications; spray and aerosolized duct sealants; non-fiberglass duct liner applications; added information on spiral duct fittings; updates to duct hanger requirements; flexible duct hanger spacing and support bracing.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Cover Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Tital page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Copyright <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | HVAC DUCT CONSTRUCTION TASK FORCE <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | NOTICE TO USERS OF THIS PUBLICATION 1. DISCLAIMER OF WARRANTIES 2. ACCEPTANCE 3. AMENDMENTS 4. PROPRIETARY PRODUCTS 5. FORMAL INTERPRETATION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 6. APPLICATION 7. REPRINT PERMISSION 8. THE SMACNA LOGO <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | MODEL PROJECT SPECIFICATION <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | LIST OF SIGNIFICANT CHANGES FROM THE THIRD EDITION <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | CHAPTER 1 ENGINEERING AND DESIGN <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 1.1 INTRODUCTION 1.2 INFORMATION REQUIRED FOR DUCT CONSTRUCTION 1.3 MODEL SPECIFICATIONS <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 1.4 DUCT SEALING <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 1.5 INTRODUCTION TO BASIC CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | CHAPTER 2 RECTANGULAR DUCT CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 2.1 INTRODUCTION TO THE RECTANGULAR DUCT CONSTRUCTION SCHEDULES <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 2.2 RECTANGULAR DUCT REINFORCEMENT <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 2.3 LONGITUDINAL SEAMS FOR RECTANGULAR DUCT <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | CHAPTER 3 ROUND, OVAL AND FLEXIBLE DUCT <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | 3.1 ROUND DUCT CONSTRUCTION STANDARDS <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | 3.2 COMMENTARY <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | 3.3 FLAT OVAL DUCT CONSTRUCTION STANDARDS 3.4 COMMENTARY <\/td>\n<\/tr>\n | ||||||
224<\/td>\n | 3.5 FLEXIBLE AIR DUCT INSTALLATION STANDARDS 3.6 SPECIFICATION FOR JOINING AND ATTACHING FLEXIBLE DUCT 3.7 SPECIFICATION FOR SUPPORTING FLEXIBLE DUCT <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | CHAPTER 4 FITTINGS AND OTHER CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | 4.1 REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
247<\/td>\n | CHAPTER 5 HANGERS AND SUPPORTS <\/td>\n<\/tr>\n | ||||||
249<\/td>\n | 5.1 HANGING AND SUPPORTING SYSTEMS 5.2 COMMENTARY <\/td>\n<\/tr>\n | ||||||
273<\/td>\n | CHAPTER 6 EXTERIOR COMPONENTS <\/td>\n<\/tr>\n | ||||||
275<\/td>\n | 6.1 INTRODUCTION <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | 6.2 ROOFTOP EQUIPMENT INSTALLATION 6.3 COMMENTARY <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | CHAPTER 7 ACCESSORIES <\/td>\n<\/tr>\n | ||||||
291<\/td>\n | 7.1 VOLUME DAMPERS 7.2 NOTES FOR FIGURES 7\u20134 AND 7\u20135 7.3 COMMENTARY <\/td>\n<\/tr>\n | ||||||
300<\/td>\n | 7.4 INSTALLATION STANDARDS FOR RECTANGULAR DUCTS USING FLEXIBLE LINER <\/td>\n<\/tr>\n | ||||||
301<\/td>\n | 7.5 COMMENTARY <\/td>\n<\/tr>\n | ||||||
302<\/td>\n | 7.6 INSTALLATION STANDARDS FOR SINGLE WALL, ROUND DUCT INSULATION DUCT LINERS 7.6.1 Single Wall Round Applications Requiring Additional Support or Mechanical Fastening: <\/td>\n<\/tr>\n | ||||||
303<\/td>\n | 7.6.2 Single Wall Round Applications Requiring Nosings: <\/td>\n<\/tr>\n | ||||||
304<\/td>\n | 7.7 COMMENTARY <\/td>\n<\/tr>\n | ||||||
309<\/td>\n | CHAPTER 8 DOUBLE\u2212WALL DUCT CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
311<\/td>\n | 8.1 INSTALLATION STANDARDS COMMENTARY <\/td>\n<\/tr>\n | ||||||
327<\/td>\n | CHAPTER 9 EQUIPMENT AND CASINGS <\/td>\n<\/tr>\n | ||||||
329<\/td>\n | 9.1 CASING AND PLENUM CONSTRUCTION STANDARDS <\/td>\n<\/tr>\n | ||||||
352<\/td>\n | 9.2 COMMENTARY 9.3 CASING ARRANGEMENT <\/td>\n<\/tr>\n | ||||||
355<\/td>\n | CHAPTER 10 SPECIALTY SYSTEMS <\/td>\n<\/tr>\n | ||||||
358<\/td>\n | 10.1 HOODS <\/td>\n<\/tr>\n | ||||||
360<\/td>\n | 10.2 UNDERGROUND DUCT CONSTRUCTION STANDARDS <\/td>\n<\/tr>\n | ||||||
363<\/td>\n | 10.3 COMMENTARY <\/td>\n<\/tr>\n | ||||||
367<\/td>\n | CHAPTER 11 FUNCTIONAL CRITERIA <\/td>\n<\/tr>\n | ||||||
369<\/td>\n | 11.1 FUNCTIONAL CRITERIA FOR DUCTS 11.2 RECTANGULAR DUCTS <\/td>\n<\/tr>\n | ||||||
370<\/td>\n | 11.3 COMMENTARY <\/td>\n<\/tr>\n | ||||||
376<\/td>\n | 11.4 PROCEDURE FOR RATING DUCT CONSTRUCTION METHODS RELATIVE TO THE SMACNA CONSTRUCTION TABLES <\/td>\n<\/tr>\n | ||||||
377<\/td>\n | 11.5 NOTES ON SPECIMEN TESTING <\/td>\n<\/tr>\n | ||||||
378<\/td>\n | 11.6 SOUND AND VIBRATION <\/td>\n<\/tr>\n | ||||||
387<\/td>\n | APPENDIX <\/td>\n<\/tr>\n | ||||||
388<\/td>\n | APPENDIX A <\/td>\n<\/tr>\n | ||||||
414<\/td>\n | CONTRIBUTORS TO THE FOURTH EDITION <\/td>\n<\/tr>\n | ||||||
416<\/td>\n | Back Cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" HVAC Duct Construction Standards – Metal and Flexible, 4th Edition<\/b><\/p>\n |