{"id":379862,"date":"2024-10-20T03:04:20","date_gmt":"2024-10-20T03:04:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-95182021\/"},"modified":"2024-10-26T05:32:23","modified_gmt":"2024-10-26T05:32:23","slug":"bs-95182021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-95182021\/","title":{"rendered":"BS 9518:2021"},"content":{"rendered":"
This British Standard gives recommendations for the processing of signals by an alarm receiving centre (ARC) from alarm systems, such as but not limited to fire detection and fire alarm systems, fixed firefighting systems, intrusion and holdup alarm systems, video surveillance systems, social alarms systems, lone worker, and combinations of such systems.<\/p>\n
\nNOTE BS EN 50518:2019 provides guidance on planning, construction, systems, management processes, leadership, governance, management and staffing of an alarm receiving centre. BS 5979 and BS 8591 also provide guidance.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 5<\/td>\n Foreword <\/td>\n<\/tr>\n \n 7<\/td>\n 1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms <\/td>\n<\/tr>\n\n 12<\/td>\n 4 General
4.1 Primary function
4.2 Working environment
4.3 Operational resources processes
4.4 Response agreement <\/td>\n<\/tr>\n\n 13<\/td>\n 4.5 Critical data omissions
4.6 Confidentiality <\/td>\n<\/tr>\n\n 14<\/td>\n 4.7 Transmission system faults
4.8 Testing of monitored alarm systems <\/td>\n<\/tr>\n\n 15<\/td>\n 4.9 Monitoring of setting and unsetting
5 Intruder and hold-up alarm monitoring
5.1 Intruder and hold-up alarm systems not utilizing confirmation technology <\/td>\n<\/tr>\n\n 16<\/td>\n 5.2 Designation of alarm signals from I&HASs capable of providing sequential confirmation
5.3 Designation of alarm signals from I&HASs capable of providing audio confirmation
5.4 Designation of alarm signals from I&HASs capable of providing visual confirmation <\/td>\n<\/tr>\n\n 17<\/td>\n 5.5 Telephone confirmation of hold-up alarm (HUA)
5.6 Transmission path conditions to be regarded as confirmation
5.7 Alarm filtering <\/td>\n<\/tr>\n\n 19<\/td>\n 5.8 Detection device inhibit signal following reinstatement of the I&HAS
6 Fire alarm systems
6.1 General <\/td>\n<\/tr>\n\n 20<\/td>\n 6.2 Filtering
6.3 Fire signals transmitted automatically via social alarm systems <\/td>\n<\/tr>\n\n 22<\/td>\n 7 Social alarm systems
8 VSS monitoring
8.1 Detection-activated remotely monitored VSS <\/td>\n<\/tr>\n\n 23<\/td>\n 8.2 ARC procedures and documentation
8.3 Activation management
9 Signals from lone worker systems <\/td>\n<\/tr>\n\n 24<\/td>\n 9.1 Service
Table 1 \u2014 Target ARC response times from receipt of activation message\/call
9.2 Operational functions <\/td>\n<\/tr>\n\n 25<\/td>\n 9.3 Oral communication
9.4 Performance criteria
9.5 Lone worker information
9.6 Establishing the nature of an incident <\/td>\n<\/tr>\n\n 26<\/td>\n 9.7 Verification
9.8 False alerts
9.9 Procedures and documentation
9.10 Access to information <\/td>\n<\/tr>\n\n 27<\/td>\n 9.11 Management of activation messages\/calls and alarm calls
Table 2 \u2014 Monthly lone worker alarm statistics (example)
Table 3 \u2014 Monthly summary of verified alarms (example) <\/td>\n<\/tr>\n\n 28<\/td>\n Annex A (informative)\u2002 Representation of the typical relationship and lines of communication between stakeholders in alarm monitoring and response
Figure A.1 \u2014 Typical relationship and lines of communication between stakeholders in alarm monitoring and response <\/td>\n<\/tr>\n\n 29<\/td>\n Annex B (informative)\u2002 Filtering actions for fire alarm signals
Figure B.1 \u2014 Response from ARC to site following receipt of a fire alarm signal (where filtering is required) <\/td>\n<\/tr>\n\n 30<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Processing of alarm signals by an alarm receiving centre. Code of practice<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2021<\/td>\n 32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":379872,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-379862","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/379862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/379872"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=379862"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=379862"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=379862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}