{"id":37197,"date":"2024-10-17T05:07:13","date_gmt":"2024-10-17T05:07:13","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e384-2005-2\/"},"modified":"2024-10-24T15:06:23","modified_gmt":"2024-10-24T15:06:23","slug":"astm-e384-2005-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e384-2005-2\/","title":{"rendered":"ASTM-E384 2005"},"content":{"rendered":"

ASTM E384-05<\/h3>\n

Historical Standard: Standard Test Method for Microindentation Hardness of Materials<\/h4>\n
\n

ASTM E384<\/h4>\n

Scope<\/strong><\/p>\n

1.1 This test method covers determination of the microindentation hardness of materials, the verification of microindentation hardness testing machines, and the calibration of standardized test blocks.<\/p>\n

1.2 This test method covers microindentation tests made with Knoop and Vickers indenters under test forces in the range from 1 to 1000 gf (9.8 10-3<\/sup> to 9.8 N).<\/p>\n

1.3 This test method includes an analysis of the possible sources of errors that can occur during microindentation testing and how these factors affect the accuracy, repeatability, and reproducibility of test results.<\/p>\n

Note 1&#8212While Committee E04 is primarily concerned with metals, the test procedures described are applicable to other materials.<\/p>\n

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n

Keywords<\/strong><\/p>\n

hardness; Knoop; microindentation; Vickers<\/p>\n

ICS Code<\/strong><\/p>\n

ICS Number Code 19.060 (Mechanical testing)<\/p>\n

DOI:<\/strong> 10.1520\/E0384-05<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology <\/td>\n<\/tr>\n
2<\/td>\nFIG. 1
FIG. 2 <\/td>\n<\/tr>\n
3<\/td>\nSummary of Test Method
Significance and Use
Apparatus <\/td>\n<\/tr>\n
4<\/td>\nTest Specimen
Procedure <\/td>\n<\/tr>\n
5<\/td>\nReport
Precision and Bias <\/td>\n<\/tr>\n
6<\/td>\nFIG. 3 <\/td>\n<\/tr>\n
7<\/td>\nConversion to Other Hardness Scales or Tensile Strength Values
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n
8<\/td>\nKeywords
A1. VERIFICATION OF KNOOP AND VICKERS HARDNESS TESTING MACHINES AND INDENTERS
A1.1 Scope
A1.2 Indenter Geometry
A1.3 Direct Verification of Microindentation Hardness Testing Machines
TABLE A1.1
FIG. A1.1
TABLE A1.2 <\/td>\n<\/tr>\n
9<\/td>\nA1.4 Indirect Verification of Microindentation Hardness Testing Machines
A1.5 Verification Report
TABLE A1.3 <\/td>\n<\/tr>\n
10<\/td>\nA2. CALIBRATION OF STANDARDIZED HARDNESS TEST BLOCKS FOR MICROINDENTATION HARDNESS TEST MACHINES
A2.1 Scope
A2.2 Test Block Manufacture
A2.3 Test Block Standardization Procedure
A2.4 Repeatability of the Standardized Test Block
A2.5 Marking
A2.6 Certification of Standardized Test Block
TABLE A2.1 <\/td>\n<\/tr>\n
11<\/td>\nX1. ADJUSTMENT OF K\u00c3\u2013HLER ILLUMINATION SYSTEMS
X1.1
X2. CORRELATION OF MICROINDENTATION HARDNESS TEST DATA BETWEEN LABORATORIES
X2.1 Scope
X2.2 Correlation Procedure
X2.3 Referee <\/td>\n<\/tr>\n
12<\/td>\nX3. RESULTS OF INTERLABORATORY TEST OF THE MEASUREMENT OF MICROINDENTATIONS
X3.1 Introduction
X3.2 Scope
X3.3 Procedure
X3.4 Results
FIG. X3.1 <\/td>\n<\/tr>\n
13<\/td>\nTABLE X3.1
TABLE X3.2
FIG. X3.2 <\/td>\n<\/tr>\n
14<\/td>\nFIG. X3.3
FIG. X3.4 <\/td>\n<\/tr>\n
15<\/td>\nX4. RECOMMENDATIONS FOR LIGHT FORCE MICROINDENTATION HARDNESS TESTING
X4.1 Introduction
X4.2 Scope
X4.3 Environment
TABLE X3.3
TABLE X3.4 <\/td>\n<\/tr>\n
16<\/td>\nX4.4 Specimens
X4.5 Instruments
X4.6 Measurement of Indentations
X4.7 Scanning Electron Microscope
X4.8 Video and Automatic Measuring Systems <\/td>\n<\/tr>\n
17<\/td>\nX5. HK AND HV VALUES FOR A 1gf TEST LOAD
X5.1
TABLE X5.1 <\/td>\n<\/tr>\n
20<\/td>\nTABLE X5.2 <\/td>\n<\/tr>\n
24<\/td>\nX6. REVISIONS
X6.1
REFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E384-05 Standard Test Method for Microindentation Hardness of Materials<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2005<\/td>\n24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":37198,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-37197","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/37197","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/37198"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=37197"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=37197"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=37197"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}