{"id":29966,"date":"2024-10-17T03:24:32","date_gmt":"2024-10-17T03:24:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-54-12\/"},"modified":"2024-10-24T14:16:20","modified_gmt":"2024-10-24T14:16:20","slug":"nfpa-54-12","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-54-12\/","title":{"rendered":"NFPA 54 12"},"content":{"rendered":"

Improve protection against fire and explosion hazards using the 2012 NFPA 54: National Fuel Gas Code. Updated for newly recognized risks and for the latest techniques, materials, developments, and construction practices in use today, the 2012 NFPA 54: National Fuel Gas Code provides revised, industry accepted guidance for the safe installation and operation of gas piping systems, appliances, equipment, and accessories. New indoor gas piping purging rules address recommendations by the U.S. Chemical Safety Board (CSB). In response to a devastating gas piping purging accident, NFPA 54 received an emergency Tentative Interim Amendment to the purging requirements in the 2009 Code. With minor editorial changes, the 2012 NFPA 54 incorporates these critical rules specifying mandatory use of combustible gas indicators and detectors so employers can identify the presence of fuel gas. Other major changes improve safety and facilitate Code application:     New bonding clamp location for CSST clarifies bonding requirements added in the 2009 edition of the Code.     Added overpressure protection for 2 psi (14 kPa) regulators improves convenience for designers and installers at industrial sites.     Two new tables make it easier to size schedule 40 steel pipe for higher pressure drops in natural gas service.     Expanded sizing tables are provided for natural gas and propane polyethylene. Annexes provide a wealth of additional information, such as:     Details on coordinating of appliance and equipment design, construction, and maintenance — including a design and construction checklist     Steps on checking for leakage and suggested emergency procedures for gas leaks Never underestimate fuel gas dangers! The 2012 National Fuel Gas Code provides a more effective means of ensuring fuel gas safety on consumers’ premises. From design to installation, maintenance, and inspection, no matter what aspect of fuel gas safety your job involves, the latest edition of NFPA 54 is essential.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nImportant Notices and Disclaimers <\/td>\n<\/tr>\n
3<\/td>\nAdditional Notices and Disclaimers <\/td>\n<\/tr>\n
4<\/td>\n2.1 General
2.2 NFPA Publications <\/td>\n<\/tr>\n
10<\/td>\nChapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Retroactivity <\/td>\n<\/tr>\n
11<\/td>\n1.4 Equivalency
1.5 Enforcement.
Chapter 2 Referenced Publications
2.3 Other Publications <\/td>\n<\/tr>\n
12<\/td>\n2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions <\/td>\n<\/tr>\n
20<\/td>\nChapter 4 General
4.1 Qualified Agency
4.2 Interruption of Service
4.3 Prevention of Accidental Ignition
Chapter 5 Gas Piping System Design, Materials, and Components
5.1 Piping Plan
5.2 Provision for Location of Point of Delivery
5.3 Interconnections Between Gas Piping Systems
5.4 Sizing of Gas Piping Systems <\/td>\n<\/tr>\n
21<\/td>\n5.5 Piping System Operating Pressure Limitations
5.6 Acceptable Piping Materials and Joining Methods <\/td>\n<\/tr>\n
23<\/td>\n5.7 Gas Meters <\/td>\n<\/tr>\n
24<\/td>\n5.8 Gas Pressure Regulators
5.9 Overpressure Protection Devices <\/td>\n<\/tr>\n
25<\/td>\n5.10 Back Pressure Protection
5.11 Low-Pressure Protection <\/td>\n<\/tr>\n
26<\/td>\n5.12 Shutoff Valves
5.13 Excess Flow Valve(s)
5.14 Expansion and Flexibility
Chapter 6 Pipe Sizing
6.1 Pipe Sizing Methods.
6.2 Tables for Sizing Gas Piping Systems Using Natural Gas
6.3 Tables for Sizing Gas Piping Systems Using Propane
6.4 Sizing Equations <\/td>\n<\/tr>\n
62<\/td>\nChapter 7 Gas Piping Installation
7.1 Piping Underground <\/td>\n<\/tr>\n
63<\/td>\n7.2 Installation of Piping
7.3 Concealed Piping in Buildings <\/td>\n<\/tr>\n
64<\/td>\n7.4 Piping in Vertical Chases
7.5 Gas Pipe Turns
7.6 Drips and Sediment Traps
7.7 Outlets <\/td>\n<\/tr>\n
65<\/td>\n7.8 Branch Pipe Connection
7.9 Manual Gas Shutoff Valves
7.10 Prohibited Devices
7.11 Systems Containing Gas\u2013Air Mixtures Outside the Flammable Range
7.12 Systems Containing Flammable Gas\u2013Air Mixtures <\/td>\n<\/tr>\n
66<\/td>\n7.13 Electrical Bonding and Grounding
7.14 Electrical Circuits
7.15 Electrical Connections
Chapter 8 Inspection, Testing, and Purging
8.1 Pressure Testing and Inspection <\/td>\n<\/tr>\n
67<\/td>\n8.2 Piping System Leak Check
8.3 Purging Requirements <\/td>\n<\/tr>\n
68<\/td>\nChapter 9 Appliance, Equipment, and Accessory Installation
9.1 General <\/td>\n<\/tr>\n
70<\/td>\n9.2 Accessibility and Clearance
9.3 Air for Combustion and Ventilation <\/td>\n<\/tr>\n
72<\/td>\n9.4 Appliances on Roofs
9.5 Appliances in Attics <\/td>\n<\/tr>\n
73<\/td>\n9.6 Appliance and Equipment Connections to Building Piping <\/td>\n<\/tr>\n
74<\/td>\n9.7 Electrical
9.8 Room Temperature Thermostats
Chapter 10 Installation of Specific Appliances
10.1 General
10.2 Air-Conditioning Appliances (Gas-Fired Air Conditioners and Heat Pumps) <\/td>\n<\/tr>\n
76<\/td>\n10.3 Central Heating Boilers and Furnaces <\/td>\n<\/tr>\n
78<\/td>\n10.4 Clothes Dryers <\/td>\n<\/tr>\n
79<\/td>\n10.5 Conversion Burners
10.6 Decorative Appliances for Installation in Vented Fireplaces
10.7 Gas Fireplaces, Vented
10.8 Non-Recirculating Direct Gas-Fired Industrial Air Heaters <\/td>\n<\/tr>\n
80<\/td>\n10.9 Recirculating Direct Gas-Fired Industrial Air Heaters
10.10 Duct Furnaces <\/td>\n<\/tr>\n
81<\/td>\n10.11 Floor Furnaces <\/td>\n<\/tr>\n
82<\/td>\n10.12 Food Service Appliance, Floor-Mounted <\/td>\n<\/tr>\n
83<\/td>\n10.13 Food Service Appliances, Counter Appliances
10.14 Hot Plates and Laundry Stoves
10.15 Household Cooking Appliances <\/td>\n<\/tr>\n
84<\/td>\n10.16 Illuminating Appliances
10.17 Incinerators, Commercial-Industrial
10.18 Infrared Heaters
10.19 Open-Top Broiler Units <\/td>\n<\/tr>\n
85<\/td>\n10.20 Outdoor Cooking Appliances
10.21 Pool Heaters
10.22 Refrigerators
10.23 Room Heaters <\/td>\n<\/tr>\n
86<\/td>\n10.24 Stationary Gas Engines
10.25 Gas-Fired Toilets
10.26 Unit Heaters
10.27 Wall Furnaces <\/td>\n<\/tr>\n
87<\/td>\n10.28 Water Heaters
10.29 Compressed Natural Gas (CNG) Vehicular Fuel Systems
10.30 Appliances for Installation in Manufactured Housing
10.31 Fuel Cell Power Plants
10.32 Outdoor Open Flame Decorative Appliances <\/td>\n<\/tr>\n
88<\/td>\nChapter 11 Procedures to Be Followed to Place Appliance in Operation
11.1 Adjusting the Burner Input
11.2 Primary Air Adjustment
11.3 Safety Shutoff Devices
11.4 Automatic Ignition
11.5 Protective Devices
11.6 Checking the Draft
11.7 Operating Instructions
Chapter 12 Venting of Appliances
12.1 Minimum Safe Performance
12.2 General
12.3 Specification for Venting <\/td>\n<\/tr>\n
89<\/td>\n12.4 Design and Construction
12.5 Type of Venting System to Be Used
12.6 Masonry, Metal, and Factory-Built Chimneys <\/td>\n<\/tr>\n
91<\/td>\n12.7 Gas Vents <\/td>\n<\/tr>\n
92<\/td>\n12.8 Single-Wall Metal Pipe <\/td>\n<\/tr>\n
93<\/td>\n12.9 Through-the-Wall Vent Termination <\/td>\n<\/tr>\n
94<\/td>\n12.10 Condensation Drain
12.11 Vent Connectors for Category I Appliances <\/td>\n<\/tr>\n
96<\/td>\n12.12 Vent Connectors for Category II, Category III, and Category IV Appliances
12.13 Draft Hoods and Draft Controls
12.14 Manually Operated Dampers
12.15 Automatically Operated Vent Dampers
12.16 Obstructions
Chapter 13 Sizing of Category I Venting Systems
13.1 Additional Requirements to Single Appliance Vent <\/td>\n<\/tr>\n
104<\/td>\n13.2 Additional Requirements to Multiple-Appliance Vent <\/td>\n<\/tr>\n
115<\/td>\nAnnex A Explanatory Material <\/td>\n<\/tr>\n
127<\/td>\nAnnex B Sizing and Capacities of Gas Piping <\/td>\n<\/tr>\n
136<\/td>\nAnnex C Suggested Method of Checking for Leakage
Annex D Suggested Emergency Procedure for Gas Leaks <\/td>\n<\/tr>\n
137<\/td>\nAnnex E Flow of Gas Through Fixed Orifices <\/td>\n<\/tr>\n
142<\/td>\nAnnex F Sizing of Venting Systems Serving Appliances Equipped with Draft Hoods, Category I Appliances, and Appliances Listed for Use with Type B Vents <\/td>\n<\/tr>\n
149<\/td>\nAnnex G Recommended Procedure for Safety Inspection of an Existing Appliance Installation <\/td>\n<\/tr>\n
150<\/td>\nAnnex H Indoor Combustion Air Calculation Examples <\/td>\n<\/tr>\n
152<\/td>\nAnnex I Example of Combination of Indoor and Outdoor Combustion and Ventilation Opening Design
Annex J Other Useful Definitions <\/td>\n<\/tr>\n
154<\/td>\nAnnex K Enforcement <\/td>\n<\/tr>\n
155<\/td>\nAnnex L Informational References <\/td>\n<\/tr>\n
158<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 54: National Fuel Gas Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2012<\/td>\n169<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":29967,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-29966","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/29966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/29967"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=29966"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=29966"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=29966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}