{"id":251920,"date":"2024-10-19T16:37:29","date_gmt":"2024-10-19T16:37:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d4553-2008-2\/"},"modified":"2024-10-25T11:55:44","modified_gmt":"2024-10-25T11:55:44","slug":"astm-d4553-2008-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d4553-2008-2\/","title":{"rendered":"ASTM-D4553 2008"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the preparation, equipment, test procedure, and data documentation for determining in situ creep characteristics of a rock mass using a rigid plate subjected to controlled loading.<\/p>\n
1.2 This test method is designed to be conducted in an underground opening; however, with suitable modifications, this test could be conducted at the surface.<\/p>\n
1.3 The test is usually conducted parallel or perpendicular to the anticipated axis of thrust, as dictated by the design load or other orientations, based upon the application.<\/p>\n
1.4 Flexible plate apparatus can be used if the anticipated creep displacement is within the tolerance of the travel of the flat jacks.<\/p>\n
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.<\/p>\n
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements, see Section 8.<\/span><\/span><\/p>\n D4553-08 Standard Test Method for Determining In Situ Creep Characteristics of Rock<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology
Summary of Test Method
Significance and Use <\/td>\n<\/tr>\n\n 2<\/td>\n Interferences
Apparatus
Precautions
In Situ Conditions <\/td>\n<\/tr>\n\n 3<\/td>\n Procedure
FIG. 1 <\/td>\n<\/tr>\n\n 4<\/td>\n FIG. 2 <\/td>\n<\/tr>\n \n 5<\/td>\n FIG. 3
FIG. 4
FIG. 5 <\/td>\n<\/tr>\n\n 6<\/td>\n Calculation
Report
Precision and Bias
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2008<\/td>\n 7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":251928,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-251920","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/251920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/251928"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=251920"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=251920"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=251920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}