{"id":182767,"date":"2024-10-19T11:26:17","date_gmt":"2024-10-19T11:26:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-standard-180-2018\/"},"modified":"2024-10-25T03:47:39","modified_gmt":"2024-10-25T03:47:39","slug":"ashrae-standard-180-2018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-standard-180-2018\/","title":{"rendered":"ASHRAE Standard 180 2018"},"content":{"rendered":"
ANSI\/ASHRAE\/ACCA Standard 180 establishes minimum HVAC inspection and maintenance requirements that preserve a system’s ability to achieve acceptable thermal comfort, energy efficiency, and indoor air quality in new and existing commercial buildings. This 2018 revision of Standard 180 includes changes that make the standard easier to implement; adds new definitions to differentiate between inspection, maintenance, service, and repair tasks; and modifies the process section to better clarify how to initiate and implement a maintenance program.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | ANSI\/ASHRAE\/ACCA Standard 180-2018 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | 1. PURPOSE 2. SCOPE 3. DEFINITIONS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 4. IMPLEMENTATION <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 5. REQUIRED INSPECTION AND MAINTENANCE TASKS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Table 5-1 Air Distribution Systems Table 5-2 Air Handlers <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Table 5-3 Boilers <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Table 5-4 Chillers\u2014Absorption <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Table 5-5 Chillers\u2014Air-Cooled <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Table 5-6 Chillers\u2014Water-Cooled <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Table 5-7 Coils and Radiators <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Table 5-8 Condensing Units <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Table 5-9 Control Systems <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Table 5-10 Cooling Towers and Evaporative-Cooled Devices <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Table 5-11 Dehumidification and Humidification Devices Table 5-12 Economizers\u2014Air Side <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Table 5-13 Engines\u2014Microturbines <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 5-14 Fan (e.g., Exhaust, Supply, Transfer, Return) Table 5-15 Fan Coils\u2014Hot-Water, and Steam Unit Heaters <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Table 5-16 Furnaces\u2014Combustion Unit Heaters Table 5-17 HVAC Water Distribution Systems <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Table 5-18 Indoor Section Duct-Free Splits <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Table 5-19 Outdoor-Air Heat-Exchanging Systems <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Table 5-20 Package Terminal Air Conditioners\/Heat Pumps (PTACs\/PTHPs) <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Table 5-21 Pumps <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Table 5-22 Rooftop Units <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Table 5-23 Steam Distribution Systems Table 5-24 Terminal and Control Boxes (e.g., VAV, Fan-Powered, Bypass) <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Table 5-25 Water-Source Heat Pumps <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | INFORMATIVE APPENDIX A\u2014INDICATORS OF UNACCEPTABLE CONDITIONS <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | INFORMATIVE APPENDIX B\u2014SOURCES OF PROGRAM OBJECTIVES <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | INFORMATIVE APPENDIX C\u2014SITUATIONS REQUIRING REVIEW OF THE MAINTENANCE PLAN <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | INFORMATIVE APPENDIX D\u2014REASONS FOR ADJUSTING MAINTENANCE TASK FREQUENCY <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | INFORMATIVE APPENDIX E\u2014BIBLIOGRAPHY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASHRAE Standard 180-2018 Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems (ANSI Approved; ACCA Co-sponsored)<\/b><\/p>\n |