BS EN ISO 21813:2022:2023 Edition
$167.15
Fine ceramics (advanced ceramics, advanced technical ceramics). Methods for chemical analysis of high purity barium titanate powders
Published By | Publication Date | Number of Pages |
BSI | 2023 | 36 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | European foreword Endorsement notice |
7 | Foreword |
9 | 1 Scope 2 Normative references 3 Terms and definitions 4 Analytes and ranges |
10 | 5 Preparation of test sample 5.1 General 5.2 Sampling 5.3 Drying |
11 | 5.4 Weighing 6 Reporting the analytical values 6.1 Number of analyses 6.2 Blank test 6.3 Evaluation of the analytical values 6.4 Expression of the analytical values 7 Determination of the barium and titanium contents 7.1 Classification of the determination methods |
12 | 7.2 Acid decomposition-gravimetric method 7.2.1 Principle 7.2.2 Reagents 7.2.3 Apparatus |
13 | 7.2.4 Procedure 7.2.5 Blank test 7.2.6 Calculation |
14 | 7.3 Acid decomposition-ICP-OES method 7.3.1 Principle 7.3.2 Reagents 7.3.3 Apparatus 7.3.4 Procedure |
15 | 7.3.5 Blank test 7.3.6 Drawing of the calibration curve 7.3.7 Calculation 8 Determination of the trace element contents 8.1 Principle 8.2 Reagents |
16 | 8.3 Apparatus 8.4 Procedure |
17 | 8.5 Blank test 8.6 Drawing of the calibration curve 8.7 Calculation 9 Determination of the total nitrogen content 9.1 Principle |
18 | 9.2 Reagents 9.3 Apparatus 9.4 Instrument |
19 | 9.5 Procedure 9.5.1 Starting up of the instrument |
20 | 9.5.2 Preliminary heating 9.5.3 Degassing of the graphite crucible 9.5.4 Measuring 9.6 Blank test 9.7 Calculation of the calibration coefficient |
21 | 9.8 Calculation 10 Determination of the oxygen content 10.1 Principle 10.2 Reagents 10.3 Apparatus 10.4 Instrument 10.5 Procedure |
22 | 10.6 Blank test 10.7 Calculation of the calibration coefficient 10.8 Calculation 11 Determination of the carbon content 11.1 Classification of the determination methods |
23 | 11.2 Combustion (resistance furnace)-IR absorption spectrometry 11.2.1 Principle 11.2.2 Reagents 11.2.3 Apparatus 11.2.4 Instrument |
24 | 11.2.5 Procedure |
25 | 11.2.6 Blank test 11.2.7 Calculation of the calibration coefficient |
26 | 11.2.8 Calculation 11.3 Combustion (radio frequency heating furnace)-thermal conductometry 11.3.1 Principle 11.3.2 Reagents 11.3.3 Apparatus 11.3.4 Instrument |
27 | 11.3.5 Procedure |
28 | 11.3.6 Blank test 11.3.7 Calculation of the calibration coefficient 11.3.8 Calculation 11.4 Combustion (radio frequency heating furnace)-IR absorption spectrometry 11.4.1 Principle 11.4.2 Reagents 11.4.3 Apparatus 11.4.4 Instrument |
29 | 11.4.5 Procedure |
30 | 11.4.6 Blank test 11.4.7 Calculation of the calibration coefficient 11.4.8 Calculation 12 Test report |
31 | Annex A (informative) Analytical results obtained from the round-robin test |
33 | Bibliography |