ASME A90.1 03:2003 Edition
$98.04
ASME A90.1 Safety Standard for Belt Manlifts
Published By | Publication Date | Number of Pages |
ASME | 2003 | 34 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS CONTENTS FIGURES FIGURES TABLES TABLES MANDATORY APPENDICES MANDATORY APPENDICES |
5 | FOREWORD FOREWORD |
6 | COMMITTEE ROSTER COMMITTEE ROSTER |
7 | CORRESPONDENCE WITH THE A90 COMMITTEE CORRESPONDENCE WITH THE A90 COMMITTEE |
8 | SUMMARY OF CHANGES SUMMARY OF CHANGES |
10 | 1 GENERAL 1 GENERAL 1.1 Scope 1.1 Scope 1.2 Purpose 1.2 Purpose 1.3 Application 1.3 Application 1.4 Exceptions 1.4 Exceptions 1.5 Units of Measurement 1.5 Units of Measurement 2 REFERENCES 2 REFERENCES 3 DEFINITIONS 3 DEFINITIONS |
11 | 4 GENERAL REQUIREMENTS 4 GENERAL REQUIREMENTS 4.1 Floor Openings 4.1 Floor Openings 4.1.1 Allowable Size 4.1.1 Allowable Size 4.1.2 Uniformity 4.1.2 Uniformity 4.2 Riding Clearance 4.2 Riding Clearance 4.3 Landings 4.3 Landings 4.3.1 Vertical Clearance 4.3.1 Vertical Clearance 4.3.2 Clear Landing Space 4.3.2 Clear Landing Space 4.3.3 Lighting of Landings 4.3.3 Lighting of Landings 4.3.4 Landing Surface 4.3.4 Landing Surface 4.3.5 Emergency Landings 4.3.5 Emergency Landings 4.4 Hoods on Underside of Floor Openings 4.4 Hoods on Underside of Floor Openings 4.4.1 Fixed Type 4.4.1 Fixed Type 1 Allowable Size for Floor Openings 1 Allowable Size for Floor Openings |
12 | 4.4.2 Floating Type 4.4.2 Floating Type 4.5 Protection of Entrances and Exits 4.5 Protection of Entrances and Exits 4.5.1 Guardrail Requirement 4.5.1 Guardrail Requirement 1 Typical Floor Openings [for 14 in. (355 mm) Belts] 1 Typical Floor Openings [for 14 in. (355 mm) Belts] |
13 | 2 Guardrail and Wall 2 Guardrail and Wall |
14 | 3 Guardrail or Screened Enclosure 3 Guardrail or Screened Enclosure |
15 | 4.5.2 Construction 4.5.2 Construction 4.5.3 Gates 4.5.3 Gates 4.5.4 Maze 4.5.4 Maze 4.5.5 Entrance Position 4.5.5 Entrance Position 4 Fixed Type Underfloor Hoods and Guardrail 4 Fixed Type Underfloor Hoods and Guardrail |
16 | 5 Maze Entrance to Manlift 5 Maze Entrance to Manlift |
17 | 4.5.6 Security 4.5.6 Security 4.6 Bottom Arrangement 4.6 Bottom Arrangement 4.6.1 Bottom Landing 4.6.1 Bottom Landing 4.6.2 Location of Bottom Pulley 4.6.2 Location of Bottom Pulley 4.6.3 Mounting Platform 4.6.3 Mounting Platform 4.6.4 Guardrails 4.6.4 Guardrails 4.7 Top Arrangement 4.7 Top Arrangement 4.7.1 Clearance From Floor 4.7.1 Clearance From Floor 4.7.2 Pulley Clearance 4.7.2 Pulley Clearance 4.8 Emergency Exit Ladder 4.8 Emergency Exit Ladder 4.9 Superstructure Bracing 4.9 Superstructure Bracing 4.10 Illumination 4.10 Illumination 4.10.1 General 4.10.1 General 4.10.2 Control of Illumination 4.10.2 Control of Illumination 4.11 Weather Protection 4.11 Weather Protection |
18 | 6 Typical Pit Location Detail (for New Installations) 6 Typical Pit Location Detail (for New Installations) |
19 | 7 Typical Lower Landing Detail 7 Typical Lower Landing Detail |
20 | 8 Head Shaft Dimensions — Top Landing 8 Head Shaft Dimensions — Top Landing |
21 | 9 Distance Between Handhold and Step 9 Distance Between Handhold and Step |
22 | 5 MECHANICAL REQUIREMENTS 5 MECHANICAL REQUIREMENTS 5.1 Machines 5.1 Machines 5.1.1 Types 5.1.1 Types 5.1.2 Brake 5.1.2 Brake 5.2 Belt 5.2 Belt 5.2.1 Material 5.2.1 Material 5.2.2 Width 5.2.2 Width 5.2.3 Strength 5.2.3 Strength 5.2.4 Belt Fastenings 5.2.4 Belt Fastenings 2 Rubber Manufacturers Association Tolerances for Width of Belting 2 Rubber Manufacturers Association Tolerances for Width of Belting |
23 | 5.2.5 Repairs Prohibited 5.2.5 Repairs Prohibited 5.2.6 Steps Prohibited 5.2.6 Steps Prohibited 5.2.7 Elevator Bolts 5.2.7 Elevator Bolts 5.2.8 Splice 5.2.8 Splice 5.2.9 Belt Location 5.2.9 Belt Location 5.3 Pulleys 5.3 Pulleys 5.3.1 Dimensions 5.3.1 Dimensions 5.3.2 Pulley Lagging 5.3.2 Pulley Lagging 5.3.3 Pulley Protection 5.3.3 Pulley Protection 5.3.4 Bottom Pulley Protection 5.3.4 Bottom Pulley Protection 5.4 Speed 5.4 Speed 5.4.1 Maximum Speed 5.4.1 Maximum Speed 5.4.2 5.4.2 5.5 Platforms or Steps 5.5 Platforms or Steps 5.5.1 Minimum Depth 5.5.1 Minimum Depth 5.5.2 Width 5.5.2 Width 3 Belt Breaking Strength 3 Belt Breaking Strength |
24 | 10 Typical Butt Splice Detail 10 Typical Butt Splice Detail |
25 | 11 Typical Lap Splice Detail 11 Typical Lap Splice Detail |
26 | 5.5.3 Distance Between Steps 5.5.3 Distance Between Steps 5.5.4 Angle of Step 5.5.4 Angle of Step 5.5.5 Surfaces 5.5.5 Surfaces 5.5.6 Strength of Step Supports 5.5.6 Strength of Step Supports 12 Typical Manual Splice Detail 12 Typical Manual Splice Detail |
27 | 5.5.7 Steps 5.5.7 Steps 5.5.8 Prohibition of Steps Without Handholds 5.5.8 Prohibition of Steps Without Handholds 5.5.9 Color 5.5.9 Color 5.6 Handholds 5.6 Handholds 5.6.1 Location 5.6.1 Location 5.6.2 Size 5.6.2 Size 5.6.3 Strength 5.6.3 Strength 5.6.4 Prohibition of Handhold Without Steps 5.6.4 Prohibition of Handhold Without Steps 5.6.5 Surfaces 5.6.5 Surfaces 5.7 Safety Stops 5.7 Safety Stops 5.7.1 Upper Limit Safety Stops 5.7.1 Upper Limit Safety Stops 5.7.2 Lower Limit Safety Stops 5.7.2 Lower Limit Safety Stops 5.7.3 Manual Reset Location 5.7.3 Manual Reset Location 5.7.4 Electrical Requirements 5.7.4 Electrical Requirements 4 Minimum Number of Bolts 4 Minimum Number of Bolts |
28 | 5.8 Start/Stop Control Rope 5.8 Start/Stop Control Rope 5.8.1 Location and Requirements 5.8.1 Location and Requirements 5.8.2 Operation 5.8.2 Operation 5.8.3 Control Rope 5.8.3 Control Rope 5.9 Factor of Safety 5.9 Factor of Safety 6 INSTRUCTION AND WARNING SIGNS 6 INSTRUCTION AND WARNING SIGNS 6.1 Instruction Signs at Landings and on Belt 6.1 Instruction Signs at Landings and on Belt 6.1.1 Size and Legibility 6.1.1 Size and Legibility 6.1.2 Inscription 6.1.2 Inscription 6.1.3 Directional Arrows 6.1.3 Directional Arrows 6.2 Top Floor Warning Sign and Light 6.2 Top Floor Warning Sign and Light 6.2.1 Requirements 6.2.1 Requirements 6.2.2 Additional Warning Light 6.2.2 Additional Warning Light 6.3 Bottom Floor Warning Sign 6.3 Bottom Floor Warning Sign 6.4 Visitor Warning Sign 6.4 Visitor Warning Sign 7 OPERATING RULES 7 OPERATING RULES 7.1 Proper Use of Manlifts 7.1 Proper Use of Manlifts |
29 | 8 TESTS AND INSPECTIONS 8 TESTS AND INSPECTIONS 8.1 Acceptance and Annual Tests 8.1 Acceptance and Annual Tests 8.1.1 Up Capacity 8.1.1 Up Capacity 8.1.2 Down Capacity — Brake 8.1.2 Down Capacity — Brake 8.1.3 Loaded Step Deflection 8.1.3 Loaded Step Deflection 8.1.4 Strength of Handhold 8.1.4 Strength of Handhold 8.1.5 Safety Stops 8.1.5 Safety Stops 8.1.6 Start/Stop Control Rope 8.1.6 Start/Stop Control Rope 8.1.7 Movable Cone Guards 8.1.7 Movable Cone Guards 8.1.8 Speed Tests 8.1.8 Speed Tests 8.1.9 Emergency Brake 8.1.9 Emergency Brake 8.1.10 Mechanical Splice 8.1.10 Mechanical Splice 8.2 Periodic Inspection 8.2 Periodic Inspection 8.2.1 Frequency 8.2.1 Frequency 8.2.2 Items Covered 8.2.2 Items Covered |
30 | 8.2.3 Unsafe Use 8.2.3 Unsafe Use 8.2.4 Inspection Log 8.2.4 Inspection Log |
32 | I RECOMMENDED TRAINING PROGRAM FOR MANLIFT PASSENGERS I RECOMMENDED TRAINING PROGRAM FOR MANLIFT PASSENGERS I-1 LECTURE I-1 LECTURE I-2 DEMONSTRATION I-2 DEMONSTRATION I-3 PRACTICE I-3 PRACTICE |
33 | II BELT MANLIFT INSPECTION REPORT WEEKLY AND MONTHLY II BELT MANLIFT INSPECTION REPORT WEEKLY AND MONTHLY |