{"id":7732,"date":"2024-10-16T19:17:17","date_gmt":"2024-10-16T19:17:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e2142\/"},"modified":"2024-10-24T10:54:39","modified_gmt":"2024-10-24T10:54:39","slug":"astm-e2142","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e2142\/","title":{"rendered":"ASTM-E2142"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1 This test method covers procedures to obtain particle size distribution, chemical classification, and Test Methods E 45 ratings of inclusions in steels using an automated scanning electron microscope (SEM) with X-ray analysis and automatic image analysis capabilities.<\/p>\n 1.2 There are three discrete methods described. Method 1 is the SEM analog of Test Method E 45, which uses image analysis and light microscopy to produce automated Test Methods E 45 ratings. Method 2 produces similar ratings based predominantly on sorting inclusions by chemistry into the traditional classes defined in Test Methods E 45. Method 3 is recommended when explicit detail is needed on particular inclusion types, not necessarily defined in Test Methods E 45, such as to verify the composition of inclusions in inclusion-engineered steel. Method 3 reports stereological parameters such as volume or number fraction, rather than Test Methods E 45 type ratings.<\/p>\n 1.3 This test method deals only with the recommended test methods and nothing in it should be construed as defining or establishing limits of acceptability for any grade of steel or other alloy where the method is appropriate.<\/p>\n 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n Keywords<\/strong><\/p>\n automatic image analysis; complex inclusions; EDX; globular inclusions; inclusions; inclusion ratings; inclusion stringers; oxides; second-phase particles; SEM; steel; stereology; sulfides; X-Ray microanalysis; Automated procedures–metals\/alloys; Inclusions–metals\/alloys; Metallographic preparation; Particle size distribution; Scanning electron microscope (SEM); Second-phase particles; SEM\/EDX processing; Stereological measurement; X-ray microanalysis<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 77.140.01 (Iron and steel products in general)<\/p>\n DOI:<\/strong> 10.1520\/E2142-08<\/p>\n<\/div>\n E2142-08 Standard Test Methods for Rating and Classifying Inclusions in Steel Using the Scanning Electron Microscope<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology <\/td>\n<\/tr>\n\n 2<\/td>\n Summary of Test Method
Significance and Use <\/td>\n<\/tr>\n\n 3<\/td>\n FIG. 1 <\/td>\n<\/tr>\n \n 4<\/td>\n Apparatus
Sampling
Test Specimens
Specimen Preparation
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n\n 5<\/td>\n Calibration and Standardization
Procedure <\/td>\n<\/tr>\n\n 6<\/td>\n Classification of Inclusions and Calculation of Severities: Method 1: the SEM analog to Test Methods
, based on Morphology, Chemistry and Thickness
Classification of Inclusions and Calculation of Severities: Method 2, based on Chemistry, Morphology and Thickness <\/td>\n<\/tr>\n\n 7<\/td>\n Classification of Inclusions: Method 3: Custom
Test Report <\/td>\n<\/tr>\n\n 8<\/td>\n FIG. 2 <\/td>\n<\/tr>\n \n 9<\/td>\n FIG. 2 <\/td>\n<\/tr>\n \n 10<\/td>\n Precision and Bias
Keywords <\/td>\n<\/tr>\n\n 11<\/td>\n FIG. 3 <\/td>\n<\/tr>\n \n 12<\/td>\n FIG. 3 <\/td>\n<\/tr>\n \n 13<\/td>\n X1. Typical Acquisition Analysis Rules
TABLE X1.1 <\/td>\n<\/tr>\n\n 14<\/td>\n X2. X-Ray Counting and Chemical Classification Statistics
X2.1 X-Ray Counting Statistics
X2.2 Stopping Criteria for X-Ray Analysis of Single Inclusion <\/td>\n<\/tr>\n\n 15<\/td>\n X2.3 Procedure for Empirically Determining the Optimal Counting Criterion <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2008<\/td>\n 15<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":7733,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1109,2637],"product_tag":[],"class_list":{"0":"post-7732","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-77-140-01","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/7732","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/7733"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=7732"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=7732"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=7732"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}