{"id":7430,"date":"2024-10-16T19:11:40","date_gmt":"2024-10-16T19:11:40","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e1719\/"},"modified":"2024-10-24T10:51:50","modified_gmt":"2024-10-24T10:51:50","slug":"astm-e1719","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e1719\/","title":{"rendered":"ASTM-E1719"},"content":{"rendered":"<\/p>\n

1.1 This test method describes procedures for determination of the vapor pressure of liquids by ebulliometry (boiling point measurements). It is applicable to pure liquids and azeotropes that have an atmospheric boiling point between 285 and 575 K and that can be condensed completely and returned to the ebulliometer boiler, that is, all materials must be condensable at total reflux. Liquid mixtures may be studied if they do not contain non-condensable components. Liquid mixtures that contain trace amounts of volatile but completely condensable components may also be studied, but they will produce vapor pressure data of greater uncertainty. Boiling point temperatures are measured at applied pressures of 1.0 to 100 kPa (7.5 to 760 torr).<\/p>\n

1.2 SI units are the standard.<\/p>\n

1.3 There is no ISO equivalent to this standard.<\/p>\n

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section .<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Summary of Test Method <\/td>\n<\/tr>\n
2<\/td>\nSignificance and Use
Interferences
Apparatus
FIG. 1 <\/td>\n<\/tr>\n
3<\/td>\nSafety Precautions
Procedure
FIG. 2 <\/td>\n<\/tr>\n
4<\/td>\nCalculation
FIG. 3 <\/td>\n<\/tr>\n
5<\/td>\nReport
Precision and Bias
Keywords <\/td>\n<\/tr>\n
6<\/td>\nA1. CHECKING EBULLIOMETER OPERATION AND CAPABILITY
A1.1 Scope
A1.2 Summary of Test
A1.3 Procedure
A1.4 Calculation
A2. SPECIFICATIONS FOR WATER, n-HEPTANE, n-DECANE, AND n-DODECANE
A2.1 Water
A2.2 n-Heptane, n-Decane, and n-Dodecane
TABLE A1.1 <\/td>\n<\/tr>\n
7<\/td>\nA3. SAMPLE CALCULATIONS AND REPORT
A3.1 Sample Experimental Data
A3.2 Sample Calculations
A3.3 Sample Vapor Pressure Report
FIG. A3.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E1719-05 Standard Test Method for Vapor Pressure of Liquids by Ebulliometry<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2005<\/td>\n7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":7431,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-7430","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/7430","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/7431"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=7430"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=7430"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=7430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}