{"id":575393,"date":"2024-11-05T19:49:35","date_gmt":"2024-11-05T19:49:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/iec-625972019\/"},"modified":"2024-11-05T19:49:35","modified_gmt":"2024-11-05T19:49:35","slug":"iec-625972019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/iec\/iec-625972019\/","title":{"rendered":"IEC 62597:2019"},"content":{"rendered":"
IEC 62597:2019 is limited to apparatus, systems and fixed installations which are intended for use in the railway environment. The frequency range covered is 0 Hz to 300 GHz.
\nTechnical considerations and measurements are specified for frequencies up to 20 kHz because no relevant field strengths are expected above due to the physical nature of EMF-sources in the railway environment.
\nThe object of this document is to provide measurement and calculation procedures of electric and magnetic field levels generated by electronic and electrical apparatus in the railway environment with respect to human exposure.
\nThe regulations regarding the protection of human beings during exposure to non-ionizing electromagnetic fields in the railway environment are different within the countries worldwide. This document offers a procedure regarding measurement, simulation\/calculation and evaluation.
\nThe measurement procedures and points of measurement cover also the aspect of persons bearing active implantable medical devices. This document does not apply to the risk assessment for persons bearing active implants in magnetic field generated by electronic and electrical apparatus in the railway environment.
\nThis first edition cancels and replaces IEC TS 62597 published in 2011. This edition includes the following significant technical changes with respect to the Technical Specification:
\na) Clause 3.1: The extent of \u201cTerms and definitions\u201d has been updated
\nb) Clause 3 was expanded by clause 3.2 \u201cabbreviated terms\u201d
\nc) Clause 4.2: The \u201csurface method\u201d for Rolling Stock measuement was deleted. Mandatory measurement method is former \u201cvolume method\u201d with slightly modified measurement heghts.
\nd) Clause 4.3: Japanese set of measurement heghts for fixed installations was deleted.
\ne) Clause 5.2 and new Annex B: Measurement technique for lower frequency range up to 5 Hz.
\nf) New Annex C: Consistency to IEC 62110 in some countries
\ng) Several editorial improvements have been included in the entire document<\/p>\n","protected":false},"excerpt":{"rendered":"
Magnetic field levels generated by electronic and electrical apparatus in the railway environment with respect to human exposure – Measurement procedures<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n IEC<\/b><\/a><\/td>\n 2019-07-17<\/td>\n 30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":575407,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[775,2636],"product_tag":[],"class_list":{"0":"post-575393","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-45-060-01","7":"product_cat-iec","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/575393","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/575407"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=575393"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=575393"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=575393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}