{"id":56046,"date":"2024-10-17T10:06:18","date_gmt":"2024-10-17T10:06:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e1938-3\/"},"modified":"2024-10-24T17:13:01","modified_gmt":"2024-10-24T17:13:01","slug":"astm-e1938-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e1938-3\/","title":{"rendered":"ASTM-E1938"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the determination of titanium in nickel alloys in the 0.3 through 5.0 % range. With appropriate reference materials the test method may be extended down to 0.05 %.<\/p>\n
1.2 Molybdenum, if present, may cause a high bias to the extent of 0.001 % Ti for every 1 % Mo.<\/p>\n
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i> For specific hazards associated with the use of this test method see Practices E 50.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Summary of Test Method Significance and Use Apparatus Reagents <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Sampling and Sample Preparation Interlaboratory Studies (ILS) Procedure TABLE 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Calculation Precision and Bias Keywords TABLE 2 TABLE 3 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" E1938-02 Standard Test Method for Determination of Titanium in Nickel Alloys by Diantipyrylmethane Molecular Absorption Spectrometric Method<\/b><\/p>\n |