{"id":504710,"date":"2024-11-05T13:44:24","date_gmt":"2024-11-05T13:44:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/as-nzs-60265-12001-r2016\/"},"modified":"2024-11-05T13:44:24","modified_gmt":"2024-11-05T13:44:24","slug":"as-nzs-60265-12001-r2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/as\/as-nzs-60265-12001-r2016\/","title":{"rendered":"AS\/NZS 60265.1:2001 (R2016)"},"content":{"rendered":"
Applies to three-phase a.c. switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from 16 2\/3 Hz up to and including 60 Hz. Is also applicable to the operating devices of these switches and to their auxiliary equipment. It is intended to be read in conjunction with AS\/NZS 2650. This Standard is technically equivalent to and contains the full content of IEC 60265:1998 and its Corrigendum:2000. <\/p>\n
Scope<\/b><\/p>\n
This Part of IEC 60265 is applicable to three-phase, alternating current switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from
16 2\/3 Hz up to and including 60 Hz.
This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.
Switch-disconnectors are also covered by IEC 60129.
General principles and provisions of this standard may also be applicable to single pole switches intended for application in single-phase systems. The requirements for dielectric tests and making and breaking tests should be in accordance with the requirements of the specific application.
NOTE 1 \u2013Except where special clarification is required, the term \u201cswitch\u201d is used to refer to all kinds of switches and switch-disconnectors within the scope of this standard.
NOTE 2 \u2013Earthing switches are not covered by this standard. Earthing switches forming an integral Part of a switch are covered by IEC 60129.
NOTE 3 \u2013This standard is not applicable to switching devices attached as an accessory to a high-voltage fuse assembly or its mounting and operated by opening and closing the fuse assembly.<\/p>\n","protected":false},"excerpt":{"rendered":"
High-voltage switches – Switches for rated voltages above 1 kV and less than 52 kV<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n AS<\/b><\/a><\/td>\n 2001-10-17<\/td>\n 65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":504725,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[510,516,588,2633],"product_tag":[],"class_list":{"0":"post-504710","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-120-40","7":"product_cat-29-130-10","8":"product_cat-31-220-20","9":"product_cat-as","11":"first","12":"instock","13":"sold-individually","14":"shipping-taxable","15":"purchasable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/504710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/504725"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=504710"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=504710"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=504710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}