{"id":446754,"date":"2024-10-20T08:48:23","date_gmt":"2024-10-20T08:48:23","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-293012023\/"},"modified":"2024-10-26T16:24:34","modified_gmt":"2024-10-26T16:24:34","slug":"bs-iso-293012023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-293012023\/","title":{"rendered":"BS ISO 29301:2023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4 Image magnification 4.1 Definition of the image magnification <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.2 Expressing magnification 5 Reference materials 5.1 General <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2 Requirements for CRM\/RM 5.3 Storage and handling 6 Calibration procedures 6.1 General <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.2 Mounting CRM\/RM 6.3 Setting TEM operating conditions for calibration <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.4 Capturing digitized image <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.5 Digitizing the image recorded on photographic film 6.5.1 General 6.5.2 How to decide the pixel-resolution for digitization <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.6 Measurement of the angle-corrected distance, Dt, from the digitized image 6.6.1 General <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.6.2 Measurement procedure <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.7 Digitization of reference scale for pixel size calibration <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.8 Calibration of image magnification 6.8.1 General 6.8.2 Calibration of scale unit (= pixel size), S <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.8.3 Calculating image magnification 6.9 Calibration of scale bar 6.9.1 General <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.9.2 Basic scale size corresponding to one pixel on the digitized image 6.9.3 Calibration of scale bar <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.10 Calibration procedure for length measurements using photographic film only 7 Accuracy of image magnification <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8 Uncertainty of measurement result <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 9 Calibration report 9.1 General 9.2 Contents of calibration report <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex A (informative) Parameters that influence the resultant magnification of a TEM <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex B (informative) Flowchart of image-magnification calibration procedure <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex C (informative) How to decide the number of lines for averaging <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Annex D (informative) Reference materials for magnification calibration <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Annex E (informative) Example of test report for calibration of TEM magnification <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Microbeam analysis. Analytical electron microscopy. Methods for calibrating image magnification by using reference materials with periodic structures<\/b><\/p>\n |