{"id":425147,"date":"2024-10-20T06:55:17","date_gmt":"2024-10-20T06:55:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-626232022\/"},"modified":"2024-10-26T13:02:25","modified_gmt":"2024-10-26T13:02:25","slug":"bs-en-iec-626232022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-626232022\/","title":{"rendered":"BS EN IEC 62623:2022"},"content":{"rendered":"

This International Standard covers personal computing products. It applies to desktop and notebook computers as defined in 4.1 that are marketed as final products and that are hereafter referred to as the equipment under test (EUT) or product. This standard specifies: – a test procedure to enable the measurement of the power and\/or energy consumption in each of the EUT’s power modes; – formulas for calculating the typical energy consumption (TEC) for a given period (normally annual); – a majority profile that should be used with this standard which enables conversion of average power into energy within the TEC formulas; – a pre-defined format for the presentation of results. This standard does not set any pass\/fail criteria for the EUTs. Users of the test results should define such criteria.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
4<\/td>\nEuropean foreword
Endorsement notice <\/td>\n<\/tr>\n
5<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
8<\/td>\nFOREWORD <\/td>\n<\/tr>\n
10<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
11<\/td>\n1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions <\/td>\n<\/tr>\n
14<\/td>\n3.2 Abbreviated terms <\/td>\n<\/tr>\n
15<\/td>\n4 Specifications for EUT
4.1 Computer descriptions
4.1.1 Desktop computer
4.1.2 Notebook computer
4.1.3 Two-in-one notebook <\/td>\n<\/tr>\n
16<\/td>\n4.1.4 Multiscreen notebook
4.1.5 Slate\/Tablet
4.1.6 Portable all-in-one computer
4.1.7 Integrated desktop computer
4.2 Power modes
4.2.1 Off mode <\/td>\n<\/tr>\n
17<\/td>\n4.2.2 Poff
4.2.3 Sleep mode
4.2.4 Psleep
4.2.5 PsleepWoL
4.2.6 Alternative low power mode
4.2.7 Palpm
4.2.8 On mode
4.2.9 Pon
4.2.10 Idle modes <\/td>\n<\/tr>\n
18<\/td>\n4.2.11 Active (work) mode
4.2.12 Pwork
4.3 Profile attributes
4.3.1 Profile <\/td>\n<\/tr>\n
19<\/td>\n4.3.2 Majority profile
4.3.3 Minority profile
4.3.4 Profile study
4.3.5 Product active power ratio
4.3.6 PAPR
4.3.7 PAWR
4.3.8 Product TEC error
4.3.9 Profile TEC error
4.4 Categorisation attributes
4.4.1 General <\/td>\n<\/tr>\n
20<\/td>\n4.4.2 Cores
4.4.3 Expandability score (ES)
4.4.4 Performance score
4.4.5 Graphics capability
4.4.6 TEC adders
5 Test procedure and conditions, categorisation, TEC formula, meter specifications and results reporting
5.1 General
5.2 Test setup <\/td>\n<\/tr>\n
21<\/td>\nTables
Table 1 \u2013 External display connection priority <\/td>\n<\/tr>\n
22<\/td>\nFigures
Figure 1 \u2013 Typical test setup <\/td>\n<\/tr>\n
23<\/td>\n5.3 Test procedure
5.3.1 General
5.3.2 Measuring off mode
5.3.3 Measuring sleep mode
5.3.4 Measuring alternative low power mode <\/td>\n<\/tr>\n
24<\/td>\n5.3.5 Measuring long idle mode
5.3.6 Measuring short idle mode <\/td>\n<\/tr>\n
25<\/td>\n5.3.7 Measuring active power mode (optional, see 5.6)
5.4 Test conditions
5.5 Categorisation
5.5.1 General
Table 2 \u2013 Test conditions <\/td>\n<\/tr>\n
26<\/td>\n5.5.2 TEC adders
5.6 Annualised energy consumption formulas
5.6.1 General
5.6.2 Estimated annualised energy consumption formula (estimated active workload) <\/td>\n<\/tr>\n
27<\/td>\n5.6.3 Measured annualised energy consumption formula (with an active workload)
Figure 2 \u2013 Example of estimated annualised energy consumption formula (estimated active workload) <\/td>\n<\/tr>\n
28<\/td>\n5.6.4 Criteria for an active workload
Figure 3 \u2013 Measured annualised energy consumption formula (with an active workload) <\/td>\n<\/tr>\n
29<\/td>\n5.7 True RMS watt meter specification <\/td>\n<\/tr>\n
30<\/td>\n5.8 True RMS watt meter accuracy <\/td>\n<\/tr>\n
31<\/td>\n5.9 Ambient light meter specification
5.10 Reporting of results
Table 3 \u2013 Ambient light meter specifications <\/td>\n<\/tr>\n
34<\/td>\nAnnex A (informative) Overview of profile methodology
Figure A.1 \u2013 Example of a typical profile <\/td>\n<\/tr>\n
36<\/td>\nAnnex B (informative) Majority profile
Table B.1 \u2013 Duty cycle attributes for the enterprise and residential majority profile duty cycle study <\/td>\n<\/tr>\n
37<\/td>\nAnnex C (informative) Method for conducting a profile study
C.1 General
C.2 Profile study example <\/td>\n<\/tr>\n
38<\/td>\nTable C.1 \u2013 Profile study 1
Table C.2 \u2013 Profile study, duty cycles <\/td>\n<\/tr>\n
39<\/td>\nTable C.3 \u2013 Profile study, TECactual and TECestimated calculations <\/td>\n<\/tr>\n
41<\/td>\nAnnex D (informative) Sample TEC calculations
D.1 General
D.2 Notebook computer example <\/td>\n<\/tr>\n
42<\/td>\nD.3 Desktop computer example <\/td>\n<\/tr>\n
43<\/td>\nAnnex E (informative) Power measurement methodology
E.1 General
E.2 Sampling method <\/td>\n<\/tr>\n
44<\/td>\nE.3 Average reading method <\/td>\n<\/tr>\n
45<\/td>\nE.4 Direct meter reading method <\/td>\n<\/tr>\n
47<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Desktop and notebook computers. Measurement of energy consumption<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2022<\/td>\n48<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":425156,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-425147","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/425147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/425156"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=425147"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=425147"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=425147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}