{"id":359669,"date":"2024-10-20T01:27:17","date_gmt":"2024-10-20T01:27:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-iec-ts-22237-22018\/"},"modified":"2024-10-26T02:10:18","modified_gmt":"2024-10-26T02:10:18","slug":"bsi-pd-iso-iec-ts-22237-22018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-iec-ts-22237-22018\/","title":{"rendered":"BSI PD ISO\/IEC TS 22237-2:2018"},"content":{"rendered":"

This document addresses the construction of buildings and other structures which provide accommodation for data centres based upon the criteria and classification for \u201cphysical security\u201d within ISO\/IEC TS 22237\u20111 in support of availability.<\/p>\n

This document specifies requirements and recommendations for the following:<\/p>\n

    \n
  1. \n

    location and site selection;<\/p>\n<\/li>\n

  2. \n

    building construction;<\/p>\n<\/li>\n

  3. \n

    building configuration;<\/p>\n<\/li>\n

  4. \n

    fire protection;<\/p>\n<\/li>\n

  5. \n

    quality construction measures.<\/p>\n<\/li>\n<\/ol>\n

    Safety and electromagnetic compatibility (EMC) requirements are outside the scope of this document and are covered by other standards and regulations. However, information given in this document may be of assistance in meeting these standards and regulations.<\/p>\n

    Conformance of data centres to the present document is covered in Clause 4.<\/p>\n

    This standard is withdrawn as it is in conflict with EN standards<\/p>\n

    PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
    PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
    2<\/td>\nNational foreword <\/td>\n<\/tr>\n
    8<\/td>\nForeword <\/td>\n<\/tr>\n
    9<\/td>\nIntroduction <\/td>\n<\/tr>\n
    11<\/td>\n1 Scope
    2 Normative references <\/td>\n<\/tr>\n
    12<\/td>\n3 Terms, definitions and abbreviated terms
    3.1 Terms and definitions <\/td>\n<\/tr>\n
    13<\/td>\n3.2 Abbreviated terms
    4 Conformance
    5 Location
    5.1 Assessment of location
    5.1.1 Requirements <\/td>\n<\/tr>\n
    14<\/td>\n5.1.2 Recommendations
    5.2 Geographical location
    5.2.1 Requirements
    5.2.2 Recommendations
    5.3 Natural environment
    5.3.1 Requirements
    5.3.2 Recommendations
    5.4 Adjacencies
    5.4.1 Requirements <\/td>\n<\/tr>\n
    15<\/td>\n5.4.2 Recommendations
    5.5 Infrastructural factors
    5.5.1 Requirements
    5.5.2 Recommendations
    6 Site configuration
    6.1 General <\/td>\n<\/tr>\n
    16<\/td>\n6.2 Site selection
    6.2.1 Requirements <\/td>\n<\/tr>\n
    17<\/td>\n6.2.2 Recommendations
    6.3 Assessment of existing premises
    6.3.1 Requirements
    6.3.2 Recommendations
    6.4 Utilities
    6.4.1 Requirements
    6.4.2 Recommendations
    6.5 Access routes
    6.5.1 Requirements
    6.5.2 Recommendations <\/td>\n<\/tr>\n
    18<\/td>\n6.6 Deliveries
    6.6.1 Requirements
    6.6.2 Recommendations
    6.7 Parking
    6.7.1 Requirements
    6.7.2 Recommendations
    6.8 Exterior installations
    6.8.1 Underground facilities
    6.8.2 Telecommunications cabling <\/td>\n<\/tr>\n
    19<\/td>\n6.9 Perimeter
    6.9.1 Requirements
    6.9.2 Recommendations
    7 Building construction
    7.1 Building structure
    7.1.1 General
    7.1.2 Load-bearing structure
    7.1.3 Building materials and finishes <\/td>\n<\/tr>\n
    20<\/td>\n7.2 Foundations
    7.2.1 Requirements
    7.2.2 Recommendations
    7.3 Exterior walls
    7.3.1 Requirements <\/td>\n<\/tr>\n
    21<\/td>\n7.3.2 Recommendations
    7.4 Interior walls providing boundaries of Protection Class
    7.4.1 Requirements
    7.4.2 Recommendations
    7.5 Roofs
    7.5.1 General <\/td>\n<\/tr>\n
    22<\/td>\n7.6 Rain water drainage
    7.6.1 Requirements
    7.6.2 Recommendations
    7.7 Floors and ceilings
    7.7.1 General
    7.7.2 Access floors <\/td>\n<\/tr>\n
    23<\/td>\n7.8 Corridors and doors
    7.8.1 Requirements
    7.8.2 Recommendations
    8 Data centre spaces and access routes
    8.1 Accommodation
    8.1.1 General
    8.1.2 Requirements
    8.1.3 Recommendations <\/td>\n<\/tr>\n
    24<\/td>\n8.1.4 Data centre spaces <\/td>\n<\/tr>\n
    25<\/td>\n8.2 Protection
    8.2.1 Requirements
    8.2.2 Recommendations
    8.3 Floors
    8.3.1 General <\/td>\n<\/tr>\n
    26<\/td>\n8.3.2 Access floors
    8.4 Ceilings
    8.4.1 Requirements
    8.4.2 Recommendations <\/td>\n<\/tr>\n
    27<\/td>\n8.5 Access to data centre spaces
    8.5.1 Requirements
    8.5.2 Recommendations
    8.6 Vapour density
    8.6.1 General
    8.6.2 Requirements
    8.6.3 Recommendations
    9 Fire compartments, fire barriers and fire suppression systems
    9.1 General
    9.1.1 Requirements <\/td>\n<\/tr>\n
    28<\/td>\n9.1.2 Recommendations
    9.2 Fire barriers
    9.2.1 Requirements
    9.2.2 Recommendations
    9.3 Fire compartments for gaseous extinguishing systems
    9.3.1 Inert gaseous extinguishing systems <\/td>\n<\/tr>\n
    29<\/td>\n9.3.2 Oxygen reduction systems
    9.4 Fire suppression
    9.4.1 Requirements
    9.4.2 Recommendations
    10 Building configurations
    10.1 Design phase
    10.1.1 Requirements
    10.1.2 Recommendations
    10.1.3 Areas, compartments <\/td>\n<\/tr>\n
    30<\/td>\n10.1.4 Modularity and flexibility
    10.2 Inter-relationship of functional spaces
    10.2.1 General
    10.2.2 Space usage
    10.2.3 Computer room space <\/td>\n<\/tr>\n
    31<\/td>\n10.2.4 Telecommunications space <\/td>\n<\/tr>\n
    32<\/td>\nAnnex A (normative) Additional requirements and recommendations <\/td>\n<\/tr>\n
    33<\/td>\nAnnex B (informative) Physical protection against external hazards <\/td>\n<\/tr>\n
    35<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

    Information technology. Data centre facilities and infrastructures – Building construction<\/b><\/p>\n\n\n\n\n
    Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
    BSI<\/b><\/a><\/td>\n2018<\/td>\n36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":359674,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-359669","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/359669","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/359674"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=359669"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=359669"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=359669"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}