{"id":291069,"date":"2024-10-19T19:45:34","date_gmt":"2024-10-19T19:45:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-145942014\/"},"modified":"2024-10-25T16:46:56","modified_gmt":"2024-10-25T16:46:56","slug":"bs-iso-145942014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-145942014\/","title":{"rendered":"BS ISO 14594:2014"},"content":{"rendered":"

This International Standard gives the general guidelines for the determination of experimental parameters relating to the primary beam, the wavelength spectrometer, and the sample that need to be taken into account when carrying out electron probe microanalysis. It also defines procedures for the determination of beam current, current density, dead time, wavelength resolution, background, analysis area, analysis depth, and analysis volume.<\/p>\n

This International Standard is intended for the analysis of a well-polished sample using normal beam incidence, and the parameters obtained can only be indicative for other experimental conditions.<\/p>\n

This International Standard is not designed to be used for energy dispersive X-ray spectroscopy.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nSection sec_1
Section sec_2
Section sec_3
Section sec_3.1
Section sec_3.2
Section sec_3.3
Section sec_3.4
Section sec_3.5
1\tScope
2\tNormative references
3\tTerms and definitions <\/td>\n<\/tr>\n
8<\/td>\nSection sec_3.6
Section sec_3.7
Section sec_3.8
Section sec_4
Section sec_5
Section sec_5.1
Section sec_5.2
Section sec_5.2.1
Section sec_5.2.2
Section sec_5.2.3
4\tAbbreviated terms
5\tExperimental parameters
5.1\tGeneral
5.2\tParameters related to the primary beam <\/td>\n<\/tr>\n
9<\/td>\nSection sec_5.2.4
Section sec_5.3
Section sec_5.3.1
Section sec_5.3.2
Section sec_5.3.3
Section sec_5.3.4
5.3\tParameters related to wavelength dispersive X-ray spectrometers <\/td>\n<\/tr>\n
10<\/td>\nSection sec_5.3.5
Section sec_5.3.6
Section sec_5.4
Section sec_5.4.1
Section sec_5.4.2
5.4\tParameters related to the specimen <\/td>\n<\/tr>\n
11<\/td>\nSection sec_5.4.3
Section sec_6
Section sec_6.1
Section sec_6.2
Section sec_6.2.1
Section sec_6.2.2
Section sec_6.2.2.1
Section sec_6.2.2.2
6\tProcedures and measurements
6.1\tGeneral
6.2\tBeam current <\/td>\n<\/tr>\n
12<\/td>\nTable tab_b
Figure fig_1
Section sec_6.3
Section sec_6.3.1
Section sec_6.3.1.1
Figure fig_2
6.3\tParameters related to measured peaks <\/td>\n<\/tr>\n
13<\/td>\nSection sec_6.3.1.2
Section sec_6.3.1.3
Section sec_6.3.2
Section sec_6.3.2.1
Section sec_6.3.2.2
Table tab_c
Figure fig_3
Section sec_6.3.3
Section sec_6.3.3.1 <\/td>\n<\/tr>\n
14<\/td>\nSection sec_6.3.3.2
Section sec_6.3.3.3
Section sec_6.4
Section sec_6.4.1
Section sec_6.4.2
Section sec_6.4.3
Section sec_6.4.4
6.4\tParameters related to the specimen <\/td>\n<\/tr>\n
15<\/td>\nSection sec_7
7\tTest report <\/td>\n<\/tr>\n
16<\/td>\nAnnex sec_A
Annex\u00a0A
\n(informative)<\/p>\n

Methods of estimating analysis area <\/td>\n<\/tr>\n

17<\/td>\nTable tab_e
Figure fig_A.1 <\/td>\n<\/tr>\n
18<\/td>\nAnnex sec_B
Annex\u00a0B
\n(informative)<\/p>\n

Methods of estimating analysis depth <\/td>\n<\/tr>\n

20<\/td>\nAnnex sec_C
Annex sec_C.1
Annex sec_C.2
Annex\u00a0C
\n(informative)<\/p>\n

Method of estimating X-ray analysis volume by applying the Monte Carlo (MC) simulation <\/td>\n<\/tr>\n

21<\/td>\nFigure fig_C.1 <\/td>\n<\/tr>\n
22<\/td>\nAnnex sec_C.3
Annex sec_C.4 <\/td>\n<\/tr>\n
23<\/td>\nFigure fig_C.2 <\/td>\n<\/tr>\n
24<\/td>\nReference ref_1
Reference ref_2
Reference ref_3
Reference ref_4
Reference ref_5
Reference ref_6
Reference ref_7
Reference ref_8
Reference ref_9
Reference ref_10
Reference ref_11
Reference ref_12
Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Microbeam analysis. Electron probe microanalysis. Guidelines for the determination of experimental parameters for wavelength dispersive spectroscopy<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2014<\/td>\n28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":291073,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1001,2641],"product_tag":[],"class_list":{"0":"post-291069","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-71-040-50","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/291069","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/291073"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=291069"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=291069"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=291069"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}