{"id":237318,"date":"2024-10-19T15:29:57","date_gmt":"2024-10-19T15:29:57","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-20-30409180-dc\/"},"modified":"2024-10-25T10:08:45","modified_gmt":"2024-10-25T10:08:45","slug":"bsi-20-30409180-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-20-30409180-dc\/","title":{"rendered":"BSI 20\/30409180 DC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4 Requirements 4.1 Workmanship 4.2 Tools 5 Pre-requisites for basic test schedule 5.1 Spring-clamp terminations 5.1.1 Materials 5.1.2 Surface finishes 5.1.3 Design features 5.1.4 Dimensions 5.2 Wires 5.2.1 Materials 5.2.2 Dimensions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.2.3 Surface finishes 5.2.4 Wire insulation 5.3 Spring-clamp connections 6 Testing 6.1 General 6.2 Standard conditions for testing 6.3 Preconditioning 6.4 Recovery 6.5 Mounting of specimen <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 7 Tests 7.1 General examination 7.2 Mechanical tests 7.2.1 Tensile strength 7.2.2 Wire deflection <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 7.2.3 Vibration <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 7.2.4 Repeated connections and disconnections <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7.3 Electrical tests 7.3.1 Contact resistance <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.3.2 Electrical load and temperature 7.4 Climatic tests 7.4.1 Rapid change of temperature 7.4.2 Climatic sequence 7.4.3 Flowing mixed gas corrosion test <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8 Test schedules 8.1 General <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 8.2 Basic test schedule 8.2.1 Initial examination 8.2.2 Testing of spring-clamp connections with spring-clamp terminations with and without a specified wire range 8.3 Full test schedule 8.3.1 Initial examination <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 8.3.2 Testing of spring type connections with and without a specified wire range 8.3.2.1 Test group A 8.3.2.2 Test group B 8.3.2.3 Test group C 8.3.2.4 Test group D <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.4 Flow charts <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Annex A (informative) Practical Guidance A.1 Current-carrying capacity A.2 Tool information A.3 Termination information A.3.1 Design features A.3.1.1 Types of spring-clamp terminations A.3.1.1.1 Universal spring-clamp terminations A.3.1.1.2 Non-universal spring-clamp terminations A.3.1.1.3 Push wire spring-clamp termination A.3.2 Materials <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | A.3.3 Surface finishes A.4 Wire information A.4.1 General A.4.2 Materials A.4.3 Surface finishes A.4.4 Stripping information <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | A.5 Connection information <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN IEC 60352-7. Solderless connections – Part 7. Spring clamp connections. General requirements, test methods and practical guidance<\/b><\/p>\n |