Intent

This Standard specifies a procedure for the measurement of the
insertion loss of a fiber optic interconnection on single mode,
highly linearly birefringent optical fiber, i.e. either
polarization-maintaining fiber (PMF) or polarizing fiber (PZF). The
connector can be mounted on the PMF/PZF pigtail of a component or
part of a cable assembly. Insertion loss, as used in this Standard,
is the measured attenuation of the interconnection, expressed in
decibels. The method described in this Standard is the PMF/PZF
equivalent of ANSI/TIA/EIA-455-171 Method D with the insertion loss
reported as a positive number.