Shopping Cart

No products in the cart.

SC SouthCarolina FireCode 2015

$61.75

South Carolina Fire Code

Published By Publication Date Number of Pages
SC 2015 583
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2015 IFC.

PDF Catalog

PDF Pages PDF Title
1 2015 SOUTH CAROLINA FIRE CODE
2 2015 SOUTH CAROLINA FIRE CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE INTERNATIONAL FIRE CODE
22 LEGISLATION
24 TABLE OF CONTENTS
32 PART I—ADMINISTRATIVE
CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—GENERAL PROVISIONS
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
SECTION 102 APPLICABILITY
33 PART 2—ADMINISTRATIVE PROVISIONS
SECTION 103 DEPARTMENT OF FIRE PREVENTION
34 SECTION 104 GENERAL AUTHORITY AND RESPONSIBILITIES
35 SECTION 105 PERMITS
38 TABLE 105.6.9 PERMIT AMOUNTS FOR COMPRESSED GASES
TABLE 105.6.11 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS
40 TABLE 105.6.21 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
TABLE 105.6.21—continued PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
43 SECTION 106 INSPECTIONS
SECTION 107 MAINTENANCE
44 SECTION 108 BOARD OF APPEALS
SECTION 109 VIOLATIONS
SECTION 110 UNSAFE BUILDINGS
45 SECTION 111 STOP WORK ORDER
SECTION 112 SERVICE UTILITIES
SECTION 113 FEES
46 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
80 PART II—GENERAL SAFETY PROVISIONS
CHAPTER 3 GENERAL REQUIREMENTS
SECTION 301 GENERAL
SECTION 302 DEFINITIONS
SECTION 303 ASPHALT KETTLES
SECTION 304 COMBUSTIBLE WASTE MATERIAL
81 SECTION 305 IGNITION SOURCES
SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM
SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
82 SECTION 308 OPEN FLAMES
84 SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
SECTION 310 SMOKING
85 SECTION 311 VACANT PREMISES
86 SECTION 312 VEHICLE IMPACT PROTECTION
SECTION 313 FUELED EQUIPMENT
SECTION 314 INDOOR DISPLAYS
SECTION 315 GENERAL STORAGE
87 SECTION 316 HAZARDS TO FIRE FIGHTERS
88 SECTION 317 ROOFTOP GARDENS AND LANDSCAPED ROOFS
SECTION 318 LAUNDRY CARTS
90 CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION 401 GENERAL
SECTION 402 DEFINITIONS
SECTION 403 EMERGENCY PREPAREDNESS REQUIREMENTS
95 SECTION 404 FIRE SAFETY, EVACUATION AND LOCKDOWN PLANS
96 SECTION 405 EMERGENCY EVACUATION DRILLS
97 TABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES
98 SECTION 407 HAZARD COMMUNICATION
100 PART III—BUILDING AND EQUIPMENT DESIGN FEATURES
CHAPTER 5 FIRE SERVICE FEATURES
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 FIRE APPARATUS ACCESS ROADS
101 SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
SECTION 505 PREMISES IDENTIFICATION
102 SECTION 506 KEY BOXES
SECTION 507 FIRE PROTECTION WATER SUPPLIES
103 SECTION 508 FIRE COMMAND CENTER
104 SECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE
108 CHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
SECTION 603 FUEL-FIRED APPLIANCES
111 SECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS
112 SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
115 SECTION 606 MECHANICAL REFRIGERATION
117 SECTION 607 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS
118 SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS
119 TABLE 608.1 BATTERY REQUIREMENTS
120 SECTION 609 COMMERCIAL KITCHEN HOODS
TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY
SECTION 610 COMMERCIAL KITCHEN COOKING OIL STORAGE
121 SECTION 611 HYPERBARIC FACILITIES
122 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION
123 SECTION 704 FLOOR OPENINGS AND SHAFTS
124 CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS
125 TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
126 SECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS
127 SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
130 SECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
132 SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS
134 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
135 TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
136 SECTION 902 DEFINITIONS
137 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
138 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
141 TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
TABLE 903.2.11.6—continued ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
143 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
147 SECTION 905 STANDPIPE SYSTEMS
149 SECTION 906 PORTABLE FIRE EXTINGUISHERS
150 TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
151 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCHa
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
161 TABLE 907.5.2.3.2 VISIBLE ALARMS
163 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
165 EQUATION 9-1
166 EQUATION 9-2
170 SECTION 910 SMOKE AND HEAT REMOVAL
171 EQUATION 9-3
EQUATION 9-4
172 SECTION 911 EXPLOSION CONTROL
173 TABLE 911.1 EXPLOSION CONTROL REQUIREMENTSf
SECTION 912 FIRE DEPARTMENT CONNECTIONS
174 SECTION 913 FIRE PUMPS
175 SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
177 TABLE 914.8.3 HANGAR FIRE SUPPRESSION REQUIREMENTS
178 SECTION 915 CARBON MONOXIDE DETECTION
180 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
SECTION 1003 GENERAL MEANS OF EGRESS
182 SECTION 1004 OCCUPANT LOAD
[BE] TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
183 SECTION 1005 MEANS OF EGRESS SIZING
184 SECTION 1006 NUMBERS OF EXITS AND EXIT ACCESS DOORWAYS
185 [BE] TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
186 [BE] TABLE 1006.3.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
[BE] TABLE 1006.3.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
187 [BE] 1006.3.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
188 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
191 SECTION 1010 DOORS, GATES AND TURNSTILES
192 [BE] TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
193 [BE] TABLE 1010.1.4(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
199 SECTION 1011 STAIRWAYS
202 SECTION 1012 RAMPS
203 SECTION 1013 EXIT SIGNS
204 SECTION 1014 HANDRAILS
205 SECTION 1015 GUARDS
207 SECTION 1016 EXIT ACCESS
208 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
[BE] TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1018 AISLES
209 SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
SECTION 1020 CORRIDORS
210 [BE] TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
[BE] TABLE 1020.2 MINIMUM CORRIDOR WIDTH
211 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
213 SECTION 1024 EXIT PASSAGEWAYS
214 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
215 SECTION 1026 HORIZONTAL EXITS
216 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
217 SECTION 1028 EXIT DISCHARGE
218 [BE] TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
219 SECTION 1029 ASSEMBLY
222 [BE] TABLE 1029.12.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
225 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
SECTION 1031 MAINTENANCE OF THE MEANS OF EGRESS
228 CHAPTER 11 CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTSa
229 TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTSa —continued
235 SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS
237 TABLE 1104.9 REVOLVING DOOR SPEEDS
239 TABLE 1104.18 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy)
240 SECTION 1105 CONSTRUCTION REQUIREMENTS FOR EXISTING GROUP I-2
TABLE 1105.2 FLOOR LEVEL LIMITATIONS FOR GROUP I-2 CONDITION 2
241 TABLE 1105.3 INCIDENTAL USES IN EXISTING GROUP I-2 OCCUPANCIES
243 SECTION 1106 REQUIREMENTS FOR OUTDOOR OPERATIONS
244 CHAPTERS 12 through 19 RESERVED
246 PART IV—SPECIAL OCCUPANCIES AND OPERATIONS
CHAPTER 20 AVIATION FACILITIES
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 AIRCRAFT MAINTENANCE
247 SECTION 2005 PORTABLE FIRE EXTINGUISHERS
SECTION 2006 AIRCRAFT FUELING
252 SECTION 2007 HELISTOPS AND HELIPORTS
254 CHAPTER 21 DRY CLEANING
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
SECTION 2103 CLASSIFICATIONS
SECTION 2104 GENERAL REQUIREMENTS
SECTION 2105 OPERATING REQUIREMENTS
255 EQUATION 21-1
SECTION 2106 SPOTTING AND PRETREATING
256 SECTION 2107 DRY CLEANING SYSTEMS
SECTION 2108 FIRE PROTECTION
258 CHAPTER 22 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION 2201 GENERAL
SECTION 2202 DEFINITION
SECTION 2203 PRECAUTIONS
SECTION 2204 EXPLOSION PROTECTION
TABLE 2204.1 EXPLOSION PROTECTION STANDARDS
260 CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 LOCATION OF DISPENSING DEVICES
SECTION 2304 DISPENSING OPERATIONS
261 SECTION 2305 OPERATIONAL REQUIREMENTS
262 SECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
263 TABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS
267 SECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
268 SECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
269 TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
270 SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
272 SECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES
273 SECTION 2311 REPAIR GARAGES
276 CHAPTER 24 FLAMMABLE FINISHES
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 PROTECTION OF OPERATIONS
278 SECTION 2404 SPRAY FINISHING
282 SECTION 2405 DIPPING OPERATIONS
283 SECTION 2406 POWDER COATING
284 SECTION 2407 ELECTROSTATIC APPARATUS
285 SECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
SECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS
286 SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS
288 CHAPTER 25 FRUIT AND CROP RIPENING
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 ETHYLENE GAS
SECTION 2504 SOURCES OF IGNITION
SECTION 2505 COMBUSTIBLE WASTE
SECTION 2506 ETHYLENE GENERATORS
SECTION 2507 WARNING SIGNS
290 CHAPTER 26 FUMIGATION AND INSECTICIDAL FOGGING
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FIRE SAFETY REQUIREMENTS
292 CHAPTER 27 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 2701 GENERAL
SECTION 2702 DEFINITIONS
SECTION 2703 GENERAL SAFETY PROVISIONS
296 SECTION 2704 STORAGE
297 TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
298 TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
SECTION 2705 USE AND HANDLING
299 TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd
302 CHAPTER 28 LUMBER YARDS AND AGRO-INDUSTRIAL, SOLID BIOMASS AND WOODWORKING FACILITIES
SECTION 2801 GENERAL
SECTION 2802 DEFINITIONS
SECTION 2803 GENERAL REQUIREMENTS
SECTION 2804 FIRE PROTECTION
303 SECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 2806 LOG STORAGE AREAS
SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST, SOLID BIOMASS FEEDSTOCK AND RAW PRODUCT ASSOCIATED WITH YARD WASTE, AGRO-INDUSTRIAL AND RECYCLING FACILITIES
304 SECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER AND SOLID BIOFUEL PRODUCTS
306 CHAPTER 29 MANUFACTURE OF ORGANIC COATINGS
SECTION 2901 GENERAL
SECTION 2902 DEFINITION
SECTION 2903 GENERAL PRECAUTIONS
SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION
307 SECTION 2905 PROCESS STRUCTURES
SECTION 2906 PROCESS MILLS AND KETTLES
SECTION 2907 PROCESS PIPING
308 SECTION 2908 RAW MATERIALS IN PROCESS AREAS
SECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS
310 CHAPTER 30 INDUSTRIAL OVENS
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
SECTION 3003 LOCATION
SECTION 3004 FUEL PIPING
SECTION 3005 INTERLOCKS
SECTION 3006 FIRE PROTECTION
SECTION 3007 OPERATION AND MAINTENANCE
312 CHAPTER 31 TENTS AND OTHER MEMBRANE STRUCTURES
SECTION 3101 GENERAL
SECTION 3102 DEFINITIONS
SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES
313 TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS
314 SECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES
316 SECTION 3105 TEMPORARY STAGE CANOPIES
318 CHAPTER 32 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 3201 GENERAL
SECTION 3202 DEFINITIONS
SECTION 3203 COMMODITY CLASSIFICATION
321 FIGURE 3203.7.4 MIXED COMMODITIESa, b
322 SECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS
SECTION 3205 HOUSEKEEPING AND MAINTENANCE
SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
323 TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
324 SECTION 3207 SOLID-PILED AND SHELF STORAGE
325 SECTION 3208 RACK STORAGE
SECTION 3209 AUTOMATED STORAGE
326 TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE
SECTION 3210 SPECIALTY STORAGE
328 CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 3301 GENERAL
SECTION 3302 DEFINITIONS
SECTION 3303 TEMPORARY HEATING EQUIPMENT
SECTION 3304 PRECAUTIONS AGAINST FIRE
329 SECTION 3305 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 3306 FLAMMABLE GASES
SECTION 3307 EXPLOSIVE MATERIALS
SECTION 3308 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
330 SECTION 3309 FIRE REPORTING
SECTION 3310 ACCESS FOR FIRE FIGHTING
SECTION 3311 MEANS OF EGRESS
SECTION 3312 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3313 STANDPIPES
SECTION 3314 AUTOMATIC SPRINKLER SYSTEM
SECTION 3315 PORTABLE FIRE EXTINGUISHERS
SECTION 3316 MOTORIZED CONSTRUCTION EQUIPMENT
331 SECTION 3317 SAFEGUARDING ROOFING OPERATIONS
332 CHAPTER 34 TIRE REBUILDING AND TIRE STORAGE
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 TIRE REBUILDING
SECTION 3404 PRECAUTIONS AGAINST FIRE
SECTION 3405 OUTDOOR STORAGE
333 SECTION 3406 FIRE DEPARTMENT ACCESS
SECTION 3407 FENCING
SECTION 3408 FIRE PROTECTION
SECTION 3409 INDOOR STORAGE ARRANGEMENT
334 CHAPTER 35 WELDING AND OTHER HOT WORK
SECTION 3501 GENERAL
SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
SECTION 3504 FIRE SAFETY REQUIREMENTS
335 SECTION 3505 GAS WELDING AND CUTTING
336 SECTION 3506 ELECTRIC ARC HOT WORK
SECTION 3507 CALCIUM CARBIDE SYSTEMS
SECTION 3508 ACETYLENE GENERATORS
SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
337 SECTION 3510 HOT WORK ON FLAMMABLE AND COMBUSTIBLE LIQUID STORAGE TANKS
338 CHAPTER 36 MARINAS
SECTION 3601 SCOPE
SECTION 3602 DEFINITIONS
SECTION 3603 GENERAL PRECAUTIONS
SECTION 3604 FIRE PROTECTION EQUIPMENT
339 SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES
340 CHAPTER 37 COMBUSTIBLE FIBERS
SECTION 3701 GENERAL
SECTION 3702 DEFINITIONS
SECTION 3703 GENERAL PRECAUTIONS
SECTION 3704 LOOSE FIBER STORAGE
341 SECTION 3705 BALED STORAGE
342 CHAPTERS 38 through 49 RESERVED
344 PART V—HAZARDOUS MATERIALS
CHAPTER 50 HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION 5001 GENERAL
346 SECTION 5002 DEFINITIONS
347 SECTION 5003 GENERAL REQUIREMENTS
349 TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
350 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
351 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
352 TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
353 TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA
354 TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREAa
356 TABLE 5003.8.2 DETACHED BUILDING REQUIRED
357 TABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS
360 TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES—NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
361 SECTION 5004 STORAGE
362 TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
364 SECTION 5005 USE, DISPENSING AND HANDLING
366 TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
368 CHAPTER 51 AEROSOLS
SECTION 5101 GENERAL
SECTION 5102 DEFINITIONS
SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS
369 TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb
TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
370 TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS
SECTION 5105 OUTSIDE STORAGE
TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
371 SECTION 5106 RETAIL DISPLAY
TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS
372 TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS
SECTION 5107 MANUFACTURING FACILITIES
374 CHAPTER 52 RESERVED
376 CHAPTER 53 COMPRESSED GASES
SECTION 5301 GENERAL
SECTION 5302 DEFINITIONS
SECTION 5303 GENERAL REQUIREMENTS
380 SECTION 5304 STORAGE OF COMPRESSED GASES
SECTION 5305 USE AND HANDLING OF COMPRESSED GASES
SECTION 5306 MEDICAL GASES
381 SECTION 5307 CARBON DIOXIDE (CO2) SYSTEMS USED IN BEVERAGE DISPENSING APPLICATIONS
382 SECTION 5308 COMPRESSED GASES NOT OTHERWISE REGULATED
384 CHAPTER 54 CORROSIVE MATERIALS
SECTION 5401 GENERAL
SECTION 5402 DEFINITION
SECTION 5403 GENERAL REQUIREMENTS
SECTION 5404 STORAGE
SECTION 5405 USE
386 CHAPTER 55 CRYOGENIC FLUIDS
SECTION 5501 GENERAL
SECTION 5502 DEFINITIONS
SECTION 5503 GENERAL REQUIREMENTS
388 SECTION 5504 STORAGE
TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS
389 TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
SECTION 5505 USE AND HANDLING
392 CHAPTER 56 EXPLOSIVES AND FIREWORKS
SECTION 5601 GENERAL
394 TABLE 5601.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVES
TABLE 5601.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVES
TABLE 5601.8.1(3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVES
395 SECTION 5602 DEFINITIONS
396 SECTION 5603 RECORD KEEPING AND REPORTING
SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING
397 TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
398 TABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
399 TABLE 5604.5.2(1)-continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
400 TABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARDa, b, c
TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4c
402 SECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS
403 TABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa
405 SECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS
406 SECTION 5607 BLASTING
407 SECTION 5608 FIREWORKS DISPLAY
408 SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS
410 CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 5701 GENERAL
SECTION 5702 DEFINITIONS
411 SECTION 5703 GENERAL REQUIREMENTS
TABLE 5703.6.2 PIPING STANDARDS
412 TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
413 TABLE 5703.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
415 SECTION 5704 STORAGE
425 TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa
427 TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
428 TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
429 TABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKSa
430 TABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa
431 TABLE 5704.3.6.3 (6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS OR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
432 TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAY
433 TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESSa, b
434 TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
435 SECTION 5705 DISPENSING, USE, MIXING AND HANDLING
436 TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1)
439 TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREASa, b
440 SECTION 5706 SPECIAL OPERATIONS
452 CHAPTER 58 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
SECTION 5801 GENERAL
SECTION 5802 DEFINITIONS
SECTION 5803 GENERAL REQUIREMENTS
453 SECTION 5804 STORAGE
SECTION 5805 USE
SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS
454 SECTION 5807 METAL HYDRIDE STORAGE SYSTEMS
455 SECTION 5808 HYDROGEN FUEL GAS ROOMS
458 CHAPTER 59 FLAMMABLE SOLIDS
SECTION 5901 GENERAL
SECTION 5902 DEFINITIONS
SECTION 5903 GENERAL REQUIREMENTS
SECTION 5904 STORAGE
SECTION 5905 USE
SECTION 5906 MAGNESIUM
460 CHAPTER 60 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 6001 GENERAL
SECTION 6002 DEFINITIONS
SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
461 SECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
464 TABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS
466 SECTION 6005 OZONE GAS GENERATORS
468 CHAPTER 61 LIQUEFIED PETROLEUM GASES
SECTION 6101 GENERAL
SECTION 6102 DEFINITIONS
SECTION 6103 INSTALLATION OF EQUIPMENT
469 SECTION 6104 LOCATION OF LP-GAS CONTAINERS
TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS
470 SECTION 6105 PROHIBITED USE OF LP-GAS
SECTION 6106 DISPENSING AND OVERFILLING
SECTION 6107 SAFETY PRECAUTIONS AND DEVICES
SECTION 6108 FIRE PROTECTION
SECTION 6109 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
471 TABLE 6109.12 SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS
472 SECTION 6110 LP-GAS CONTAINERS NOT IN SERVICE
SECTION 6111 PARKING AND GARAGING OF LP-GAS TANK VEHICLES
474 CHAPTER 62 ORGANIC PEROXIDES
SECTION 6201 GENERAL
SECTION 6202 DEFINITION
SECTION 6203 GENERAL REQUIREMENTS
SECTION 6204 STORAGE
475 TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES
476 SECTION 6205 USE
478 CHAPTER 63 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
SECTION 6301 GENERAL
SECTION 6302 DEFINITIONS
SECTION 6303 GENERAL REQUIREMENTS
479 TABLE 6303.2 STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS
SECTION 6304 STORAGE
TABLE 6304.1.5(1) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS
480 TABLE 6304.1.5(2) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.1.5(3) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.2.1 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6305 USE
SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE
484 CHAPTER 64 PYROPHORIC MATERIALS
SECTION 6401 GENERAL
SECTION 6402 DEFINITION
SECTION 6403 GENERAL REQUIREMENTS
SECTION 6404 STORAGE
485 TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6405 USE
486 CHAPTER 65 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 6501 GENERAL
SECTION 6502 DEFINITIONS
SECTION 6503 GENERAL REQUIREMENTS
SECTION 6504 STORAGE AND HANDLING
488 CHAPTER 66 UNSTABLE (REACTIVE) MATERIALS
SECTION 6601 GENERAL
SECTION 6602 DEFINITION
SECTION 6603 GENERAL REQUIREMENTS
SECTION 6604 STORAGE
489 SECTION 6605 USE
490 CHAPTER 67 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 6701 GENERAL
SECTION 6702 DEFINITION
SECTION 6703 GENERAL REQUIREMENTS
SECTION 6704 STORAGE
491 SECTION 6705 USE
492 CHAPTERS 68 through 79 RESERVED
494 PART VI—REFERENCED STANDARDS
CHAPTER 80 REFERENCED STANDARDS
AASHTO
AFSI
ANSI
API
495 ASCE/SEI
ASHRAE
ASME
496 ASSE
ASTM
497 BHMA
CA
CGA
498 CGR
CPSC
DOC
DOL
499 DOTn
DOTy
EN
FCC
500 FM
ICC
501 IIAR
IKECA
ISO
NEMA
502 NFPA
504 UL
505 USC
506 PART VII—APPENDICES
APPENDIX A BOARD OF APPEALS
SECTION A101 GENERAL
508 APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B101 GENERAL
SECTION B102 DEFINITIONS
SECTION B103 MODIFICATIONS
SECTION B104 FIRE-FLOW CALCULATION AREA
SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS
TABLE B105.1(1) REQUIRED FIRE-FLOW FOR ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES
509 TABLE B105.1(2) REFERENCE TABLE FOR TABLES B105.1(1) AND B105.2
TABLE B105.2 REQUIRED FIRE-FLOW FOR BUILDINGS OTHER THAN ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES
510 SECTION B106 REFERENCED STANDARDS
512 APPENDIX C FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION C101 GENERAL
SECTION C102 NUMBER OF FIRE HYDRANTS
TABLE C102.1 REQUIRED NUMBER AND SPACING OF FIRE HYDRANTS
SECTION C103 FIRE HYDRANT SPACING
SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS
513 SECTION C105 REFERENCED STANDARDS
514 APPENDIX D FIRE APPARATUS ACCESS ROADS
SECTION D101 GENERAL
SECTION D102 REQUIRED ACCESS
SECTION D103 MINIMUM SPECIFICATIONS
TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND
515 FIGURE D103.6 FIRE LANE SIGNS
SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS
516 SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
SECTION D108 REFERENCED STANDARDS
518 APPENDIX E HAZARD CATEGORIES
SECTION E101 GENERAL
SECTION E102 HAZARD CATEGORIES
522 SECTION E103 EVALUATION OF HAZARDS
523 SECTION E104 REFERENCED STANDARDS
524 APPENDIX F HAZARD RANKING
SECTION F101 GENERAL
SECTION F102 REFERENCED STANDARDS
525 TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES
526 APPENDIX G CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS
SECTION G101 GENERAL
527 TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS
528 APPENDIX H HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS
SECTION H101 HMMP
SECTION H102 HMIS
529 SECTION H103 EMERGENCY PLAN
SECTION H104 REFERENCED STANDARDS
530 FIGURE 1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
531 FIGURE 2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
532 FIGURE 3 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION PART C—FACILITY MAP
533 FIGURE 4 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS SUMMARY REPORTa (Storageb Conditions)c
534 FIGURE 5 SECTION II — HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS INVENTORY REPORT (Sort Products Alphabetically by Location of Product and then Alphabetically by Product Name)
535 FIGURE 6 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION III: EMERGENCY PLAN
536 APPENDIX I FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS
SECTION I101 NONCOMPLIANT CONDITIONS
537 SECTION I102 REFERENCED STANDARDS
538 APPENDIX J BUILDING INFORMATION SIGN
SECTION J101 GENERAL
FIGURE J101.1.3 EXAMPLE OF COMPLETED BUILDING INFORMATION SIGN
540 SECTION J102 REFERENCED STANDARDS
542 APPENDIX K CONSTRUCTION REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
SECTION K101 GENERAL
SECTION K102 FIRE SAFETY REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
SECTION K103 INCIDENTAL USES IN EXISTING AMBULATORY CARE FACILITIES
543 TABLE K103.1 INCIDENTAL USES IN EXISTING AMBULATORY CARE FACILITIES
SECTION K104 MEANS OF EGRESS REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
544 SECTION K105 REFERENCED STANDARDS
546 APPENDIX L REQUIREMENTS FOR FIRE FIGHTER AIR REPLENISHMENT SYSTEMS
SECTION L101 GENERAL
SECTION L102 DEFINITIONS
SECTION L103 PERMITS
SECTION L104 DESIGN AND INSTALLATION
548 SECTION L105 ACCEPTANCE TESTS
SECTION L106 INSPECTION, TESTING AND MAINTENANCE
SECTION L107 REFERENCED STANDARDS
550 APPENDIX M HIGH-RISE BUILDINGS—RETROACTIVE AUTOMATIC SPRINKLER REQUIREMENT
SECTION M101 SCOPE
SECTION M102 WHERE REQUIRED
SECTION M103 COMPLIANCE
SECTION M104 REFERENCED STANDARDS
552 INDEX
SC SouthCarolina FireCode 2015
$61.75