BSI PD CEN/TS 1401-2:2020
$142.49
Plastics piping systems for non-pressure underground drainage and sewerage. Unplasticized poly(vinyl chloride) (PVC-U) – Guidance for the assessment of conformity
Published By | Publication Date | Number of Pages |
BSI | 2020 | 28 |
This document gives requirements and guidance for the assessment of conformity of formulations, products and assemblies in accordance with EN 1401?1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [ 1].
If third party certification is involved, the certification body is expected be compliant with either EN ISO/IEC 17065 [ 2] or EN ISO/IEC 17021-series [ 3], as applicable.
In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1401?1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended for non-pressure underground drainage and sewerage:
-
buried in ground outside the building structure (application area code “U”);
-
both buried in ground within the building structure and outside the building structure (application area code “UD”) .
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
11 | 4 Abbreviated terms 5 General |
12 | 6 Testing and inspection 6.1 Material specification |
13 | 6.2 Grouping 6.2.1 General 6.2.2 Size groups 6.2.3 Fitting groups |
14 | 6.3 Type testing |
17 | 6.4 Batch release tests |
20 | 6.5 Process verification tests |
21 | 6.6 Audit tests |
23 | 6.7 Indirect tests |
24 | 6.8 Test records |
25 | Annex A (informative)Basic test matrix |