BS ISO 8600-2:2002
$102.76
Optics and optical instruments. Medical endoscopes and endoscopic accessories – Particular requirements for rigid bronchoscopes
Published By | Publication Date | Number of Pages |
BSI | 2002 | 22 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | TitlePage – Optics and optical instrumentsļæ½ā Medical endoscopes and endoscopic accessoriesļæ½ā |
5 | TableofContent – Contents Page |
6 | Foreword – Foreword |
7 | Introduction – Introduction |
9 | Scope – 1ļæ½ļæ½ļæ½ Scope NormativeReference – 2ļæ½ļæ½ļæ½ Normative references |
10 | Clause1 – 4ļæ½ļæ½ļæ½ Requirements Subclause2 – 4.1ļæ½ļæ½ļæ½ General Subclause2 – 4.2ļæ½ļæ½ļæ½ Dimensions Subclause3 – 4.2.1ļæ½ļæ½ļæ½ Working length Subclause3 – 4.2.2ļæ½ļæ½ļæ½ Overall length |
11 | Subclause3 – 4.2.3ļæ½ļæ½ļæ½ Maximum insertion portion width Subclause2 – 4.3ļæ½ļæ½ļæ½ Rigid ventilation bronchoscopes UntitledSubclause3 – 4.3.1ļæ½ļæ½ļæ½ A rigid ventilation bronchoscope shall be provided with an integral… UntitledSubclause3 – 4.3.2ļæ½ļæ½ļæ½ A rigid ventilation bronchoscope shall be provided, in a side-arm, … Subclause2 – 4.4ļæ½ļæ½ļæ½ Rigid jet-ventilation bronchoscopes UntitledSubclause3 – 4.4.1ļæ½ļæ½ļæ½ Rigid jet-ventilation bronchoscopes shall be provided with a jet-in… UntitledSubclause3 – 4.4.2ļæ½ļæ½ļæ½ When tested in accordance with UntitledSubclause3 – 4.4.3ļæ½ļæ½ļæ½ When tested in accordance with Subclause2 – 4.5ļæ½ļæ½ļæ½ Side apertures UntitledSubclause3 – 4.5.1ļæ½ļæ½ļæ½ Side apertures, if provided, shall be located on the rigid bronchos… UntitledSubclause3 – 4.5.2ļæ½ļæ½ļæ½ The minimum total area of the side apertures shall not be less than… |
12 | UntitledSubclause3 – 4.5.3ļæ½ļæ½ļæ½ The side apertures shall have a smooth rounded finish. |
14 | Clause1 – 5ļæ½ļæ½ļæ½ Testing Subclause2 – 5.1ļæ½ļæ½ļæ½ General Subclause2 – 5.2ļæ½ļæ½ļæ½ Test method for pressure drop Subclause3 – 5.2.1ļæ½ļæ½ļæ½ Purpose Subclause3 – 5.2.2ļæ½ļæ½ļæ½ Apparatus UntitledSubclause4 – 5.2.2.1ļæ½ļæ½ļæ½ Flow-measuring device UntitledSubclause4 – 5.2.2.2ļæ½ļæ½ļæ½ Pressure-measuring device UntitledSubclause4 – 5.2.2.3ļæ½ļæ½ļæ½ Buffer reservoir Subclause3 – 5.2.3ļæ½ļæ½ļæ½ Procedure UntitledSubclause4 – 5.2.3.1ļæ½ļæ½ļæ½ Carry out the test at UntitledSubclause4 – 5.2.3.2ļæ½ļæ½ļæ½ Set up the apparatus as shown in UntitledSubclause4 – 5.2.3.3ļæ½ļæ½ļæ½ Adjust the airflow to the flow specified in Subclause2 – 5.3ļæ½ļæ½ļæ½ Test method for security of attachment of a jet-injector to the rigid broncho… Subclause3 – 5.3.1ļæ½ļæ½ļæ½ Purpose Subclause3 – 5.3.2ļæ½ļæ½ļæ½ Apparatus UntitledSubclause4 – 5.3.2.1ļæ½ļæ½ļæ½ Rigid jet-injection bronchoscope UntitledSubclause4 – 5.3.2.2ļæ½ļæ½ļæ½ Means UntitledSubclause4 – 5.3.2.3ļæ½ļæ½ļæ½ Bracket Subclause3 – 5.3.3ļæ½ļæ½ļæ½ Procedure UntitledSubclause4 – 5.3.3.1ļæ½ļæ½ļæ½ Carry out the test at UntitledSubclause4 – 5.3.3.2ļæ½ļæ½ļæ½ Attach the jet-injector to the rigid jet-ventilation bronchoscope… |
15 | UntitledSubclause4 – 5.3.3.3ļæ½ļæ½ļæ½ Mount the rigid jet-ventilation bronchoscope so that the jet-inje… Subclause3 – 5.3.4ļæ½ļæ½ļæ½ Expression of results Subclause2 – 5.4ļæ½ļæ½ļæ½ Method of test for container pressure with an open-ended jet-injector broncho… Subclause3 – 5.4.1ļæ½ļæ½ļæ½ Purpose Subclause3 – 5.4.2ļæ½ļæ½ļæ½ Apparatus UntitledSubclause4 – 5.4.2.1ļæ½ļæ½ļæ½ Rigid jet-ventilation bronchoscope |
16 | UntitledSubclause4 – 5.4.2.2ļæ½ļæ½ļæ½ Adjustable pressure regulator UntitledSubclause4 – UntitledSubclause4 – 5.4.2.4ļæ½ļæ½ļæ½ Clamp Subclause3 – 5.4.3ļæ½ļæ½ļæ½ Procedure UntitledSubclause4 – 5.4.3.1ļæ½ļæ½ļæ½ Carry out the test at UntitledSubclause4 – 5.4.3.2ļæ½ļæ½ļæ½ Set the adjustable pressure regulator at Subclause3 – 5.4.4ļæ½ļæ½ļæ½ Expression of results |
17 | Subclause2 – 5.5ļæ½ļæ½ļæ½ Test method for minimum instrument channel width Subclause3 – 5.5.1ļæ½ļæ½ļæ½ Purpose Subclause3 – 5.5.2ļæ½ļæ½ļæ½ Apparatus UntitledSubclause4 – 5.5.2.1ļæ½ļæ½ļæ½ Stand with clamp UntitledSubclause4 – 5.5.2.2ļæ½ļæ½ļæ½ Steel ball Subclause3 – 5.5.3ļæ½ļæ½ļæ½ Procedure UntitledSubclause4 – 5.5.3.1ļæ½ļæ½ļæ½ Carry out the test at UntitledSubclause4 – 5.5.3.2ļæ½ļæ½ļæ½ Clamp the bronchoscope in a vertical position with the proximal e… UntitledSubclause4 – 5.5.3.3ļæ½ļæ½ļæ½ Record whether or not the steel ball passes freely through the lu… Clause1 – 6ļæ½ļæ½ļæ½ Marking Clause1 – 7ļæ½ļæ½ļæ½ Instruction manual UntitledSubclause2 – 7.1ļæ½ļæ½ļæ½ Clauseļæ½7 of UntitledSubclause2 – 7.2ļæ½ļæ½ļæ½ Items d)ļæ½4), d)ļæ½5), f)ļæ½1), and f)ļæ½2) of clauseļæ½7 of UntitledSubclause2 – 7.3ļæ½ļæ½ļæ½ Item d)ļæ½3) of clauseļæ½7 of UntitledSubclause2 – 7.4ļæ½ļæ½ļæ½ Item d) of clauseļæ½7 of UntitledSubclause2 – 7.5ļæ½ļæ½ļæ½ Item a) of clauseļæ½7 of UntitledSubclause2 – 7.6ļæ½ļæ½ļæ½ Item f) of clauseļæ½7 of UntitledSubclause2 – 7.7ļæ½ļæ½ļæ½ The maximum pressure as measured in accordance to |
18 | UntitledSubclause2 – 7.8ļæ½ļæ½ļæ½ When a jet-injector is used with a rigid ventilation bronchoscope tha… Clause1 – 8ļæ½ļæ½ļæ½ Packaging |
19 | AnnexInformative – Rationale |