BS IEC 60479-1:2018 – TC:2020 Edition

$280.87

Tracked Changes. Effects of current on human beings and livestock – General aspects

Published By Publication Date Number of Pages
BSI 2020 171
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60479-1:2018(E) provides basic guidance on the effects of shock current on human beings and livestock. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. It is not intended for use by manufacturers or certification bodies.

PDF Catalog

PDF Pages PDF Title
97 undefined
99 CONTENTS
103 FOREWORD
105 INTRODUCTION
106 1 Scope
107 2 Normative references
3 Terms and definitions
3.1 General definitions
108 3.2 Effects of sinusoidal alternating current in the range 15 Hz to 100 Hz
109 3.3 Effects of direct current
110 4 Electrical impedance of the human body and livestock
4.1 General
4.2 Internal impedance of the human body (Zi)
4.3 Impedance of the skin (Zs)
4.4 Total impedance of the human body (ZT)
111 4.5 Factors affecting initial resistance of the human body (R0)
4.6 Values of the total impedance of the human body (ZT)
4.6.1 Total body impedance dependence for large, medium and small surface areas of contact
4.6.2 Sinusoidal alternating current 50/60 Hz for large surface areas of contact
112 Tables
Table 1 – Total body impedances ZT for a current path hand to hand AC 50/60 Hz, for large surface areas of contact in dry conditions
113 Table 2 – Total body impedances ZT for a current path hand to hand AC 50/60 Hz, for large surface areas of contact in water-wet conditions
114 4.6.3 Sinusoidal alternating current 50/60 Hz for medium and small surface areas of contact
Table 3 – Total body impedances ZT for a current path hand to hand AC 50/60 Hz, for large surface areas of contact in saltwater-wet conditions
115 Table 4 –Total body impedances ZT for a current path hand to hand for medium surface areas of contact in dry conditions at touch voltages UT = 25 V to 200 V AC 50/60 Hz (values rounded to 25 Ω)
116 Table 5 – Total body impedances ZT for a current path hand to hand for medium surface areas of contact in water-wet conditions at touch voltages UT = 25 V to 200 V AC 50/60 Hz (values rounded to 25 Ω)
Table 6 – Total body impedances ZT for a current path hand to hand for medium surface areas of contact in saltwater-wet conditions at touch voltages UT = 25 V to 200 V AC 50/60 Hz (values rounded to 5 Ω)
Table 7 – Total body impedances ZT for a current path hand to hand for small surface areas of contact in dry conditions at touch voltages UT = 25 V to 200 V AC 50/60 Hz (values rounded to 25 Ω)
117 4.6.4 Sinusoidal alternating current with frequencies up to 20 kHz and above
Table 8 – Total body impedances ZT for a current path hand to hand for small surface areas of contact in water-wet conditions at touch voltages UT = 25 V to 200 V AC 50/60 Hz (values rounded to 25 Ω)
Table 9 – Total body impedances ZT for a current path hand to hand for small surface areas of contact in saltwater-wet conditions at touch voltages UT = 25 V to 200 V AC 50/60 Hz (values rounded to 5 Ω)
118 4.6.5 Direct current
Table 10 – Total body resistances RT for a current path hand to hand, direct current, for large surface areas of contact in dry conditions
119 4.7 Value of the initial resistance of the human body (R0)
4.8 Characteristics of the impedance of the body of livestock
5 Effects of sinusoidal alternating current in the range of 15 Hz to 150 Hz
5.1 General
5.2 Threshold of perception
5.3 Threshold of reaction
5.4 Immobilization
120 5.5 Threshold of let-go
5.6 Threshold of ventricular fibrillation
5.7 Other effects related to electric shocks
121 5.8 Effects of current on the skin
5.9 Description of time/current zones (see Figure 20)
122 5.10 Application of heart-current factor (F)
Table 11 – Time/current zones for AC 15 Hz to 100 Hz for hand to feet pathway – Summary of zones of Figure 20
123 6 Effects of direct current
6.1 General
6.2 Threshold of perception and threshold of reaction
6.3 Threshold of immobilization and threshold of let-go
6.4 Threshold of ventricular fibrillation
Table 12 – Heart-current factor F for different current paths
124 6.5 Other effects of current
6.6 Description of time/current zones (see Figure 22)
125 6.7 Heart factor
Figures
Figure 1 – Impedances of the human body
Table 13 – Time/current zones for direct current for hand to feet pathway –Summary of zones of Figure 22
126 Figure 2 – Internal partial impedances Zip of the human body
127 Figure 3 – Simplified schematic diagram for the internal impedances of the human body
128 Figure 4 – Total body impedance ZT (50 %) for a current path hand to hand, for large surface areas of contact in dry, water-wet and saltwater-wet conditions for a percentile rank of 50 % of the population for touch voltages UT = 25 V to 700 V, AC 50/60 Hz
129 Figure 5 – Dependence of the total impedance ZT of one living person on the surface area of contact in dry conditions and at touch voltage (50 Hz)
130 Figure 6 – Dependence of the total body impedance ZT on the touch voltage UT for a current path from the tips of the right to the left forefinger compared with large surface areas of contact from the right to the left hand in dry conditions measured on one living person, touch voltage range UT = 25 V to 200 V, AC 50 Hz, duration of current flow max. 25 ms
131 Figure 7 – Dependence of the total body impedance ZT for the 50th percentile rank of a population of living human beings for large, medium and small surface areas of contact (order of magnitude 10 000 mm2, 1 000 mm2 and 100 mm2 respectively) in dry conditions at touch voltages UT = 25 V to 200 V AC 50/60 Hz
132 Figure 8 – Dependence of the total body impedance ZT for the 50th percentile rank of a population of living human beings for large, medium and small surface areas of contact (order of magnitude 10 000 mm2, 1 000 mm2 and 100 mm2 respectively) in water-wet conditions at touch voltages UT = 25 V to 200 V, AC 50/60 Hz
133 Figure 9 – Dependence of the total body impedance ZT for the 50th percentile rank of a population of living human beings for large, medium and small surface areas of contact (order of magnitude 10 000 mm2, 1 000 mm2 and 100 mm2 respectively) in saltwater-wet conditions at touch voltages UT = 25 V to 200 V, AC 50/60 Hz
134 Figure 10 – Values for the total body impedance ZT measured on 10 living human beings with a current path hand to hand and large surface areas of contact in dry conditions at a touch voltage of 10 V and frequencies from 25 Hz to 20 kHz
Figure 11 – Values for the total body impedance ZT measured on one living human being with a current path hand to hand and large surface areas of contact in dry conditions at a touch voltage of 25 V and frequencies from 25 Hz to 2 kHz
135 Figure 12 – Frequency dependence of the total body impedance ZT of a population for a percentile rank of 50 % for touch voltages from 10 V to 1 000 V and a frequency range from 50 Hz to 150 kHz for a current path hand to hand or hand to foot, large surface areas of contact in dry conditions
Figure 13 – Statistical value of total body impedances ZT and body resistances RT for a percentile rank of 50 % of a population of living human beings for the current path hand to hand, large surface areas of contact, dry conditions, for touch voltages up to 700 V, for AC 50/60 Hz and DC
136 Figure 14 – Dependence of the alteration of human skin condition on current density iT and duration of current flow
137 Figure 15 – Electrodes used for the measurement of the dependence of the impedance of the human body ZT on the surface area of contact
138 Figure 16 – Oscillograms of touch voltages UT and touch currents IT for AC, current path hand to hand, large surface areas of contact in dry conditions taken from measurements
139 Figure 17 – Occurrence of the vulnerable period of ventricles during the cardiac cycle
Figure 18 – Triggering of ventricular fibrillation in the vulnerable period – Effects on electro-cardiogram (ECG) and blood pressure
140 Figure 19 – Fibrillation data for dogs, pigs and sheep from experiments and for persons calculated from statistics of electrical accidents with transversal direction of current flow hand to hand and touch voltages UT = 220 V and 380 V AC with body impedances ZT (5 %)
141 Figure 20 – Conventional time/current zones of effects of AC currents (15 Hz to 100 Hz) on persons for a current path corresponding to left hand to feet (see Table 11)
Figure 21 – Oscillogram of touch voltages UT and touch current IT for DC, current path hand to hand, large surface areas of contact in dry conditions
142 6.8 Effects of anodic versus cathodic DC currents
Figure 22 – Conventional time/current zones of effects of DC currents on persons for a longitudinal upward current path (see Table 13)
Figure 23 – Let-go currents for 60 Hz sinusoidal current
143 Figure 24 – Effects of anodic versus cathodic DC currents
144 Figure 25 – Pulsed DC stimulation of single heart cells
145 Annex A (normative)Measurements of the total body impedances ZT made on living human beings and on corpses and statistical analysis of the results
Table A.1 – Total body impedances ZT, electrodes type A for dry conditions and deviation factors FD (5 % and 95 %)
Table A.2 – Total body impedances ZT, electrodes type B for dry, water-wet and saltwater-wet conditions and deviation factors FD (5 % and 95 %)
Table A.3 – Total body impedances ZT for dry, water-wet and saltwater-wet conditions and deviation factors FD (5 % and 95 %)
147 Table A.4 – Deviation factors FD (5 %) and FD (95 %) for dry and water-wet conditionsin the touch voltage range UT = 25 V up to 400 V for large, medium and small surface areas of contact
148 Annex B (normative)Influence of frequency on the total body impedance (ZT)
149 Annex C (normative)Total body resistance (RT) for direct current
150 Annex D (informative)Examples of calculations of ZT
151 Table D.1 – 50th percentile values for the total body impedance for a current path hands-feet, medium surface area of contact for hands, large for feet, reduction factor 0,8, dry conditions, touch currents IT and electrophysiological effects
153 Annex E (informative)Theories of ventricular fibrillation
154 Annex F (informative)Quantities of upper limit of vulnerability (ULV)and lower limit of vulnerability (LLV)
155 Annex G (informative)Circuit simulation methods in electric shock evaluation
156 Figure G.1 – Electric shock in electrical model by Hart [33]including startle reaction effect
Table G.1 – Body impedance examples (uncompensated)
158 Annex H (normative)Effects of currents passing through the body of livestock
H.1 General
H.2 Principal consideration of the risk of ventricular fibrillation for livestock
159 H.3 Characteristics of the impedance of the body of livestock
H.4 Internal impedance of animals (Zi)
Figure H.1 – Current flow and impedances of the relevant parts of the body of a cow for current path from the nose to the legs
Figure H.2 – Diagrams for an animal, for a current path from the nose to the four legs (path A) and from the forelegs to the hind legs (path B)
160 H.5 Impedance of the hide and skin (ZP)
H.6 Impedance (resistance) of the hoof (Zh, Rh)
H.7 Total body impedance (ZT)
Table H.1 – Impedance (resistance) of the hooves of cattle (Zh, Rh) for ACvoltages up to 230 V, 50/60 Hz
161 H.8 Initial body resistance (R0)
H.9 Values of the total body impedance (ZT)
Table H.2 – Total body impedances ZT for AC 50/60 Hz forcattle for touch voltages up to 230 V
162 H.10 Values of the initial resistance of the body (R0)
H.11 Effects on livestock of sinusoidal alternating current in the range from 15 Hz to 100 Hz
H.11.1 General
Figure H.3 – Diagram for the total body impedance for cattle for a percentage of 5 % of the population
Table H.3 – Initial body resistance R0 for cattle
163 H.11.2 Threshold of reaction
H.11.3 Threshold of ventricular fibrillation
Figure H.4 – Ventricular fibrillation for sheep
164 Figure H.5 – Minimum fibrillating currents of sheep as a function of weight for a shock duration of 3 s [55]
Table H.4 – Threshold of ventricular fibrillation for AC 50/60 Hz [53] [54] for different species of livestock, for a shock duration of 3 s
165 Figure H.6 – Minimum fibrillating currents (averages) of various species of livestockas a function of weight for a shock duration of 3 s [53]
166 Bibliography
BS IEC 60479-1:2018 - TC
$280.87