2 | undefined |
7 | Annex ZA(informative)Relationship between this European Standard and the essential requirements of Directive 2014/32/EU aimed to be covered |
13 | Blank Page |
14 | Blank Page |
17 | Foreword |
18 | Section sec_1 Section sec_2 1 Scope 2 Normative references |
19 | Section sec_3 Section sec_4 3 Terms and definitions 4 Reference conditions |
20 | Section sec_5 Section sec_6 Section sec_6.1 Section sec_6.2 Section sec_6.3 5 Symbols, units and equations 6 External examination 6.1 General 6.2 Object of the examination 6.3 Preparation |
21 | Section sec_6.4 Section sec_6.4.1 Section sec_6.4.2 Section sec_6.4.3 Section sec_6.4.3.1 Section sec_6.4.3.2 Section sec_6.4.3.3 6.4 Examination procedures |
22 | Section sec_6.4.3.4 Section sec_6.4.3.5 Section sec_6.4.3.5.1 Section sec_6.4.3.5.2 |
23 | Section sec_6.4.3.5.3 Section sec_6.4.3.6 Section sec_6.4.3.6.1 Section sec_6.4.3.6.2 Section sec_6.4.3.6.2.1 |
24 | Section sec_6.4.3.6.2.2 Section sec_6.4.3.6.2.3 |
25 | Section sec_6.4.4 Section sec_7 Section sec_7.1 Section sec_7.2 Section sec_7.2.1 Section sec_7.2.2 Section sec_7.2.2.1 7 Performance tests for all water meters 7.1 General 7.2 Required conditions for all tests |
26 | Section sec_7.2.2.2 Section sec_7.2.2.3 Section sec_7.3 Section sec_7.3.1 Section sec_7.3.2 Section sec_7.3.3 Section sec_7.3.3.1 Section sec_7.3.3.2 7.3 Static pressure test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.10) |
27 | Section sec_7.3.4 Section sec_7.4 Section sec_7.4.1 Section sec_7.4.2 Section sec_7.4.2.1 7.4 Determination of intrinsic errors (of indication) (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.3) |
28 | Section sec_7.4.2.2 Section sec_7.4.2.2.1 Section sec_7.4.2.2.2 Section sec_7.4.2.2.3 |
29 | Section sec_7.4.2.2.4 Section sec_7.4.2.2.4.1 Section sec_7.4.2.2.4.2 Section sec_7.4.2.2.4.3 Section sec_7.4.2.2.4.4 Section sec_7.4.2.2.4.5 |
30 | Section sec_7.4.2.2.4.6 Section sec_7.4.2.2.5 Section sec_7.4.2.2.5.1 Section sec_7.4.2.2.5.2 Section sec_7.4.2.2.5.3 |
31 | Section sec_7.4.2.2.6 Section sec_7.4.2.2.6.1 Section sec_7.4.2.2.6.2 Section sec_7.4.2.2.7 Section sec_7.4.2.2.7.1 Section sec_7.4.2.2.7.2 Section sec_7.4.2.2.7.3 |
32 | Section sec_7.4.2.2.7.4 Section sec_7.4.2.2.7.5 |
33 | Section sec_7.4.3 Section sec_7.4.3.1 Section sec_7.4.3.2 Section sec_7.4.4 |
34 | Section sec_7.4.5 Section sec_7.4.6 Section sec_7.4.6.1 Section sec_7.4.6.2 Section sec_7.4.6.3 |
35 | Section sec_7.4.6.4 Section sec_7.5 Section sec_7.5.1 Section sec_7.5.2 Section sec_7.5.3 Section sec_7.5.4 Section sec_7.6 Section sec_7.6.1 Section sec_7.6.2 Section sec_7.6.3 7.5 Water temperature test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.8) 7.6 Overload water temperature test (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.5) |
36 | Section sec_7.6.4 Section sec_7.7 Section sec_7.7.1 Section sec_7.7.2 Section sec_7.7.3 Section sec_7.7.4 Section sec_7.8 Section sec_7.8.1 7.7 Water pressure test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.8) 7.8 Reverse flow test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.7) |
37 | Section sec_7.8.2 Section sec_7.8.3 Section sec_7.8.3.1 Section sec_7.8.3.2 Section sec_7.8.3.3 |
38 | Section sec_7.8.4 Section sec_7.9 Section sec_7.9.1 Section sec_7.9.2 7.9 Pressure loss test (ISO 4064-1:2014|OIML R 49‑1:2013, 6.5) |
39 | Table tab_b Figure fig_1 Section sec_7.9.3 Section sec_7.9.3.1 Section sec_7.9.3.2 |
41 | Table tab_c Figure fig_2 Section sec_7.9.4 Section sec_7.9.5 |
42 | Section sec_7.10 Section sec_7.10.1 Section sec_7.10.2 Section sec_7.10.3 Section sec_7.10.4 7.10 Flow disturbance tests (ISO 4064-1:2014|OIML R 49‑1:2013, 6.3.4) |
43 | Section sec_7.11 Section sec_7.11.1 Section sec_7.11.2 Section sec_7.11.2.1 Section sec_7.11.2.2 Section sec_7.11.2.2.1 Section sec_7.11.2.2.2 Section sec_7.11.2.2.3 7.11 Durability tests (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.6) |
44 | Section sec_7.11.2.2.4 Section sec_7.11.2.3 Section sec_7.11.2.3.1 Section sec_7.11.2.3.2 Section sec_7.11.2.3.3 Section sec_7.11.2.3.4 |
45 | Section sec_7.11.2.3.5 Section sec_7.11.2.3.6 Table tab_1 |
46 | Section sec_7.11.2.4 Section sec_7.11.2.4.1 Section sec_7.11.2.4.2 Section sec_7.11.3 Section sec_7.11.3.1 Section sec_7.11.3.2 Section sec_7.11.3.2.1 Section sec_7.11.3.2.2 |
47 | Section sec_7.11.3.2.3 Section sec_7.11.3.3 Section sec_7.11.3.3.1 Section sec_7.11.3.3.2 Section sec_7.11.3.3.3 Section sec_7.11.3.3.4 |
48 | Section sec_7.11.3.3.5 Section sec_7.11.3.4 Section sec_7.11.3.4.1 Section sec_7.11.3.4.2 Section sec_7.12 Section sec_7.13 Section sec_7.13.1 7.12 Magnetic field testing 7.13 Tests on ancillary devices of a water meter |
49 | Section sec_7.13.2 Section sec_7.13.3 Section sec_7.13.4 Section sec_7.14 Section sec_8 Section sec_8.1 Section sec_8.1.1 7.14 Environmental testing 8 Performance tests related to influence factors and disturbances 8.1 General requirements (ISO 4064-1:2014|OIML R 49‑1:2013, A.1) |
50 | Section sec_8.1.2 Section sec_8.1.3 Section sec_8.1.4 Section sec_8.1.5 Section sec_8.1.6 |
51 | Section sec_8.1.7 Section sec_8.1.8 Section sec_8.1.8.1 |
52 | Section sec_8.1.8.2 Section sec_8.1.8.3 Section sec_8.1.8.4 |
53 | Section sec_8.1.8.5 Section sec_8.2 Section sec_8.2.1 Section sec_8.2.2 Section sec_8.2.3 8.2 Dry heat (non-condensing) (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
54 | Section sec_8.2.4 Section sec_8.3 Section sec_8.3.1 Section sec_8.3.2 Section sec_8.3.3 Section sec_8.3.4 8.3 Cold (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
55 | Section sec_8.4 Section sec_8.4.1 Section sec_8.4.2 Section sec_8.4.3 8.4 Damp heat, cyclic (condensing) (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
56 | Section sec_8.4.4 Section sec_8.5 Section sec_8.5.1 Section sec_8.5.2 Section sec_8.5.2.1 Section sec_8.5.2.2 Section sec_8.5.2.3 8.5 Power supply variation (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
57 | Figure fig_3 Section sec_8.5.2.4 |
58 | Section sec_8.5.3 Section sec_8.5.3.1 Section sec_8.5.3.2 Section sec_8.5.3.3 Section sec_8.5.3.4 Section sec_8.5.4 Section sec_8.5.4.1 |
59 | Section sec_8.5.4.2 Section sec_8.5.4.3 Section sec_8.6 Section sec_8.6.1 Section sec_8.6.2 Section sec_8.6.3 8.6 Vibration (random) (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
60 | Section sec_8.6.4 Section sec_8.7 Section sec_8.7.1 Section sec_8.7.2 Section sec_8.7.3 8.7 Mechanical shock (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
61 | Section sec_8.7.4 Section sec_8.8 Section sec_8.8.1 Section sec_8.8.2 Section sec_8.8.3 8.8 AC mains voltage dips, short interruptions and voltage variations (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
62 | Table tab_2 Table tab_3 Section sec_8.8.4 Section sec_8.9 Section sec_8.9.1 8.9 Bursts on signal lines (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
63 | Section sec_8.9.2 Section sec_8.9.3 Section sec_8.9.4 |
64 | Section sec_8.10 Section sec_8.10.1 Section sec_8.10.2 Section sec_8.10.3 Section sec_8.10.4 8.10 Bursts (transients) on AC and DC mains (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
65 | Section sec_8.11 Section sec_8.11.1 Section sec_8.11.2 Section sec_8.11.3 8.11 Electrostatic discharge (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
66 | Section sec_8.11.4 Section sec_8.12 Section sec_8.12.1 Section sec_8.12.2 Section sec_8.12.3 8.12 Radiated electromagnetic fields (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
68 | Table tab_4 Section sec_8.12.4 Section sec_8.13 Section sec_8.13.1 Section sec_8.13.2 Section sec_8.13.3 8.13 Conducted electromagnetic fields (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
69 | Table tab_5 Section sec_8.13.4 |
70 | Section sec_8.14 Section sec_8.14.1 Section sec_8.14.2 Section sec_8.14.3 8.14 Surges on signal, data and control lines (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
71 | Section sec_8.14.4 Section sec_8.15 Section sec_8.15.1 Section sec_8.15.2 Section sec_8.15.3 8.15 Surges on AC and DC mains power lines (ISO 4064-1:2014|OIML R 49‑1:2013, A.5) |
72 | Section sec_8.15.4 Section sec_8.16 Section sec_8.16.1 Section sec_8.16.2 8.16 Static magnetic field (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.8) |
73 | Section sec_8.16.3 Section sec_8.16.4 Section sec_8.16.5 Section sec_8.17 Section sec_8.17.1 Section sec_8.17.2 Section sec_8.17.3 8.17 Absence of flow test |
74 | Section sec_8.17.4 Section sec_9 Section sec_9.1 Section sec_9.2 Table tab_6 9 Test program for type evaluation 9.1 Number of samples required 9.2 Performance test applicable to all water meters |
75 | Section sec_9.3 Section sec_9.4 9.3 Performance tests applicable to electronic water meters, mechanical water meters fitted with electronic devices, and their separable parts 9.4 Type evaluation of separable parts of a water meter |
76 | Section sec_9.5 Section sec_10 Section sec_10.1 Section sec_10.1.1 Section sec_10.1.2 Section sec_10.1.3 9.5 Families of water meters 10 Tests for initial verification 10.1 Initial verification of complete and combined water meters |
77 | Section sec_10.1.4 Section sec_10.2 Section sec_10.2.1 10.2 Initial verification of separable parts of a water meter |
78 | Section sec_10.2.2 Section sec_10.2.3 Section sec_10.2.4 Section sec_11 Section sec_11.1 Section sec_11.2 Section sec_11.2.1 11 Presentation of results 11.1 Object of the reports 11.2 Identification and test data to be included in records |
79 | Section sec_11.2.2 |
80 | Annex sec_A Annex sec_A.1 Annex sec_A.2 Annex sec_A.3 Annex sec_A.3.1 Annex A (normative) Type examination and testing of checking facilities of electronic devices |
81 | Annex sec_A.3.2 Annex sec_A.3.2.1 Annex sec_A.3.2.2 Annex sec_A.3.2.2.1 |
82 | Annex sec_A.3.2.2.2 Annex sec_A.3.2.2.3 Annex sec_A.3.3 Annex sec_A.3.3.1 Annex sec_A.3.3.2 Annex sec_A.3.3.2.1 |
83 | Annex sec_A.3.3.2.2 Annex sec_A.3.4 Annex sec_A.3.4.1 Annex sec_A.3.4.2 |
84 | Annex sec_A.3.5 Annex sec_A.3.5.1 Annex sec_A.3.5.2 Annex sec_A.3.6 Annex sec_A.3.6.1 |
85 | Annex sec_A.3.6.2 |
86 | Annex sec_B Annex sec_B.1 Annex sec_B.2 Annex B (normative) Calculating the relative error (of indication) of a water meter |
87 | Annex sec_B.3 Annex sec_B.3.1 Annex sec_B.3.2 Annex sec_B.3.3 Annex sec_B.3.3.1 |
88 | Annex sec_B.3.3.2 Annex sec_B.3.3.3 |
89 | Annex sec_B.3.3.4 Annex sec_B.3.4 Annex sec_B.3.4.1 |
90 | Annex sec_B.3.4.2 Annex sec_B.3.4.3 |
91 | Annex sec_B.3.4.4 |
92 | Annex sec_C Annex C (normative) Installation requirements for flow disturbance tests |
93 | Table tab_v Figure fig_C.1 |
94 | Annex sec_D Annex sec_D.1 Annex sec_D.2 Annex sec_D.3 Annex D (normative) Type evaluation of a family of water meters |
95 | Figure fig_D.1 |
96 | Annex sec_E Table tab_w Figure fig_E.1 Annex E (informative) Examples of methods and components used for testing concentric water meters |
97 | Table tab_x Figure fig_E.2 |
98 | Table tab_y Figure fig_E.3 |
99 | Annex sec_F Annex sec_F.1 Annex sec_F.2 Annex F (informative) Determining the density of water |
100 | Annex sec_F.3 Table tab_F.1 |
101 | Annex sec_G Annex sec_G.1 Annex sec_G.2 Annex sec_G.3 Annex G (informative) Maximum uncertainties in the measurement of influence factors and disturbances |
102 | Annex sec_G.4 Annex sec_G.5 Annex sec_G.6 Annex sec_G.7 Annex sec_G.8 |
103 | Annex sec_G.9 Annex sec_G.10 |
104 | Annex sec_H Annex sec_H.1 Annex sec_H.2 Annex sec_H.3 Annex H (informative) Pressure loss test pressure tappings, hole and slot details |
105 | Table tab_an Figure fig_H.1 Table tab_ao Figure fig_H.2 |
106 | Table tab_ap Figure fig_H.3 |
107 | Annex sec_I Annex sec_I.1 Annex sec_I.2 Table tab_aq Figure fig_I.1 Annex I (normative) Flow disturbers |
108 | Table tab_ar Figure fig_I.2 Table tab_as Figure fig_I.3 |
109 | Table tab_I.1 Table tab_at Figure fig_I.4 |
110 | Table tab_I.2 Table tab_au Figure fig_I.5 |
111 | Table tab_I.3 Figure fig_I.6 Table tab_I.4 |
112 | Figure fig_I.7 Table tab_I.5 |
113 | Table tab_av Figure fig_I.8 Table tab_aw Figure fig_I.9 |
114 | Table tab_ax Figure fig_I.10 |
115 | Table tab_I.6 |
116 | Table tab_ay Figure fig_I.11 Table tab_I.7 |
117 | Figure fig_I.12 Table tab_I.8 |
118 | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Reference ref_5 Reference ref_6 Reference ref_7 Reference ref_8 Reference ref_9 Reference ref_10 Reference ref_11 Reference ref_12 Bibliography |