BS EN IEC 62442-1:2022
$142.49
Energy performance of lamp controlgear – Controlgear for fluorescent lamps. Method of measurement to determine the total input power of controlgear circuits and the efficiency of controlgear
Published By | Publication Date | Number of Pages |
BSI | 2022 | 26 |
IEC 62442-1:2022 is available as IEC 62442-1:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62442-1:2022 defines a measurement and calculation method of the total input power for controlgear-lamp circuits when operating with their associated fluorescent lamp(s). The calculation method for the efficiency of the lamp controlgear is also defined. This document applies to electrical controlgear-lamp circuits consisting only of the controlgear and the lamp(s). It is intended for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – this edition has been harmonized with IEC 62442-2 and IEC 62442-3; – the reference to and use of the measurement methods for non-active power consumption in accordance with IEC 63103 have been added.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
6 | Blank Page |
7 | English CONTENTS |
9 | FOREWORD |
11 | 1 Scope 2 Normative references |
12 | 3 Terms and definitions |
14 | 4 General 4.1 Ballast lumen factor |
15 | 4.2 Dimmable controlgear 4.3 Multi-power and/or multi-number-lamp controlgear 4.4 General notes on tests 4.5 Sampling of controlgear for testing 4.6 Size of the test sample 4.7 Conditioning of lamps 4.8 Test voltages and frequencies |
16 | 4.9 Sensor and network connections 5 Method of measurement and calculation of total input power of controlgear�lamp circuits and the efficiency of controlgear 5.1 Correction for ballast lumen factor 5.2 Method of measurement Table 1 – Typical nominal electricity supply details for some regions |
17 | 5.3 Measurement and calculation of the total input power of magnetic controlgear�lamp circuits 5.4 Calculation of the efficiency of electromagnetic controlgear 5.5 Measurement and calculation of the total input power of electronic controlgear�lamp circuits |
19 | 5.6 Calculation of the efficiency of electronic controlgear 5.7 Measuring the standby power 5.8 Measuring the networked standby power 5.9 Reporting of power measurements |
20 | Annex A (normative) Energy performance measurement set-up A.1 Measurement set-up for electromagnetic controlgear A.2 Measurement set-up for electronic controlgear A.2.1 Measurement of the total input power Figure A.1 – Measurement of electromagnetic controlgear-lamp circuits |
21 | A.2.2 Light output measurement Figure A.2 – Measurement of AC supplied electroniccontrolgear-lamp circuits Figure A.3 – Side view of light output measurement system |
22 | A.2.3 Distance to lamp related to lamp length: explanations Figure A.4 – Top view of light output measurement system |
23 | Figure A.5 – Configuration of lamp and photocell sensor |
24 | Annex B (informative) Application of the reference ballast when assessing lamps in electronic operation B.1 Calculation of the reference ballast impedance B.2 Method of adjusting the lamp power |
25 | Bibliography |