IEC 61988-2-1:2012 determines the following measuring methods for characterizing the performance of plasma display modules (PDP modules): a) four per cent (4 %) window luminance; b) luminance uniformity; c) dark-room contrast ratio; d) bright-room contrast ratio 100/70; e) white chromaticity and chromatic uniformity; f) colour gamut in the centre box; g) module power and current consumption; h) module power consumption using video signal; i) module luminous efficacy, and j) panel luminous efficacy. This edition includes the following significant technical changes with respect to the previous edition: The first edition of IEC 61988-2-1 and IEC 61988-2-2 were combined and reconstructed in this document.

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
8 1 Scope
2 Normative references
3 Terms and definitions
9 4 Structure of measuring equipment
5 Standard measuring conditions
5.1 Environmental conditions
5.2 Set-up conditions
5.2.1 General
10 5.2.2 Measuring layout
5.2.3 Field frequency
Figures
Figure 1 – Measuring layout (side view)
11 5.2.4 Adjustment of PDP modules
5.2.5 Warm-up condition of PDP modules
5.3 Lighting conditions
5.3.1 Dark-room conditions
5.3.2 Bright-room conditions
12 Figure 2 – Example of bright-room conditions
13 6 Measuring methods
6.1 Measuring methods of 4 % window luminance
6.1.1 Purpose
6.1.2 Measuring equipment
6.1.3 Measurement
Figure 3 – Four per cent (4 %) window luminance measuring pattern
14 6.2 Measuring method of luminance uniformity
6.2.1 Purpose
6.2.2 Measuring equipment
6.2.3 Measurement
15 6.3 Measuring method of dark-room contrast ratio
6.3.1 Purpose
6.3.2 Measuring equipment
Figure 4 – Measuring points
Tables
Table 1 – Example of luminance uniformity measurement
16 6.3.3 Measurement
17 6.4 Measuring method of bright-room contrast ratio 100/70
6.4.1 General
6.4.2 Purpose
6.4.3 Measuring equipment
6.4.4 Measurement
Figure 5 – Minimum luminance measuring pattern
18 6.5 Measuring method of white chromaticity and chromatic uniformity
6.5.1 Purpose
6.5.2 Measuring equipment
6.5.3 Measurement
19 6.6 Measuring method of colour gamut
6.6.1 Purpose
6.6.2 Measuring equipment
6.6.3 Measurement
Table 2 – Example of chromaticity measurement
20 6.7 Measuring method of module power and current consumption
6.7.1 Purpose
6.7.2 Measuring equipment
Figure 6 – Example of the colour gamut measurement
21 6.7.3 Measurement
Figure 7 – Example of power and current measuring diagram
22 Table 3 – Example of power and current measurements (for a module that includes an AC input)
Table 4 – Example of power and current measurement (for a module with DC inputs only)
23 6.8 Measuring method of module power consumption using video signal
6.8.1 General
6.8.2 Measuring equipment
6.8.3 Applied digital video signal
6.8.4 Image processing board
24 6.8.5 Measurement
Table 5 – Example of measurement results of module power consumption using video signal
25 6.9 Measuring method of module luminous efficacy
6.9.1 Purpose
6.9.2 Measuring equipment
6.9.3 Measurement
26 6.10 Measuring method of panel luminous efficacy
6.10.1 Purpose
6.10.2 Measuring equipment
27 6.10.3 Panel conditions
Figure 8 – System diagram of sustain power measurement
28 6.10.4 Driving waveform
29 6.10.5 Applied display patterns
6.10.6 Measurement
Figure 9 – Driving system and waveform
33 Annex A (informative) Clause cross-references from the previous edition of IEC 61988-2-1:2002 and IEC 61988-2-2:2003 to IEC 61988-2-1:2011
34 Table A.1 – Clause cross-references
35 Bibliography