BS EN 50288-2-2:2013

$102.76

Multi-element metallic cables used in analogue and digital communication and control – Sectional specification for screened cables characterised up to 100 MHz. Work area and patch cord cables

Published By Publication Date Number of Pages
BSI 2013 22
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

EN 50288-2-2 is a sectional specification for screened cables, characterised from 1 MHz up to 100 MHz, to be used as work area cables to connect a telecommunications outlet to the terminal equipment and for patch cord cables to establish connections on a patch panel as defined in EN 50173. Work area and data centres cables may also be used as patch cord cables in any distributor of a generic building wiring system to interconnect with equipment or to cross-connect between cabling systems

This sectional specification contains the electrical, mechanical, transmission and environmental performance characteristics of the cables, when tested in accordance with the referenced test methods.

This sectional specification is to be read in conjunction with EN 50288-1 which contains the essential provisions for its application.

The cables covered in this sectional specification are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains.

PDF Catalog

PDF Pages PDF Title
6 1 Scope
2 Normative references
3 Terms definitions, symbols and abbreviations
3.1 Terms and definitions
For the purposes of this document the terms and definitions given in EN 50288-1 and the following apply.
7 3.1.1 screening of cable
cable that is considered screened when the cable core is covered by a continuous conductive layer forming part of the shielding and grounding system
Note 1 to entry: d.c. continuity has to be given and minimum shielding requirements have to be met.
3.2 Symbols and abbreviations
4 Cable construction
4.1 Conductor
4.2 Insulation
The insulation shall be of a suitable material according to the relevant part of EN 50290-2.
4.3 Cabling elements
The cable element shall be a pair or a quad.
4.4 Identification of cabling elements
4.5 Screening of cabling elements
4.6 Cable make-up
The cable elements shall be laid up in concentric layer(s) or units to form the cable core.
4.7 Filling compound
Not applicable.
4.8 Interstitial fillers
Where fillers are used they shall meet the requirements of EN 50288-1, 4.8 and 4.9.
8 4.9 Screening of the cable core
4.10 Moisture barriers
Not applicable
4.11 Wrapping layers
4.12 Sheath
The sheath shall be of a suitable material according to the relevant part of EN 50290-2.
5 Tests and requirements for completed cables
5.1 Electrical tests
5.1.1 Low-frequency and d.c. electrical measurements
Table 1 – Low-frequency and d.c. electrical measurements
9 5.1.2 High-frequency electrical and transmission measurements
11 5.2 Mechanical tests
12 5.3 Environmental tests
5.4 Fire performance tests
13 Annex A (informative) Maximum voltage, current and temperature rating for cables used for POE applications
14 Annex B (informative) Blank Detail Specification
BS EN 50288-2-2:2013
$102.76