ASTM-F2188:2011 Edition
$35.75
F2188-02(2011) Standard Test Method for Determining the Effect of Variable Frequency Vibration on a Membrane Switch or Membrane Switch Assembly
Published By | Publication Date | Number of Pages |
ASTM | 2011 | 2 |
ASTM F2188-02-Reapproved2011
Historical Standard: Standard Test Method for Determining the Effect of Variable Frequency Vibration on a Membrane Switch or Membrane Switch Assembly
ASTM F2188
Scope
1.1 This test method establishes procedures for determining the effect of sinusoidal vibration, within the specified frequency range, on switch contacts, mounting hardware, adhered component parts, solder or heat stakes, tactile devices, and cable or ribbon interconnects associated with a membrane switch or membrane switch assembly.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
contact closure; frequency; membrane switch; vibration; Cable interconnect; Contact closure; Electronic mounting hardware; Frequency membrane switch; Membrane switches; Random variables/variation; Random vibration test; Ribbon interconnect; Sinusoidal motion/vibration; Switch contacts; Vibration test
ICS Code
ICS Number Code 29.120.40 (Switches)
DOI: 10.1520/F2188-02R11
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Terminology Significance and Use Apparatus ProcedureāTest Condition A, 10 g |
2 | ProcedureāTest Condition B, 20 g Report Keywords |