1.1 This test method describes the procedures to determine the opacity of a plume. The aforementioned plume is caused by particulate matter emitted from a stationary point source in the outdoor ambient environment using digital imagery and associated software and hardware.

1.2 The opacity of emissions is determined by the application of a Digital Camera Opacity Technique (DCOT) that consists of a Digital Still Camera, Analysis Software, and the Output Function s content to obtain and interpret digital images to determine and report plume opacity.

1.3 This method is suitable to determine the opacity of plumes from zero (0) percent to one hundred (100) percent.

1.4 This test method is not applicable to stacks with internal diameters greater than 7.0 ft.

1.5 Conditions that shall be considered when using this method to obtain the digital image of the plume include the plume s background, the existence of condensed water in the plume, orientation of the Digital Still Camera to the plume and the sun (see Section 8).

1.6 This standard describes the procedures to certify the DCOT, hardware, software, and method to determine the opacity of the plumes.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Test Method
Significance and Use
Interferences
3 TABLE 1
4 System Description
Procedures
5 Certification of DCOT and DCOT Operator
6 Precision and Bias
TABLE 2
TABLE 3
7 Keywords
A1. PRINCIPLES OF VISUAL EMISSIONS MEASUREMENTS AND PROCEDURES TO EVALUATE THOSE EMISSIONS USING DIGITAL CAMERA OPTICAL TECHNIQUE (DCOT)
A1.1 Abstract
A1.2 Table of Contents
8 A1.3 List of Figures
A1.4 Principles of Visual Emissions Measurement
FIG. A1.1
9 FIG. A1.2
FIG. A1.3
FIG. A1.4
10 FIG. A1.5
FIG. A1.6
FIG. A1.7
FIG. A1.8
11 A1.5 Method 9 Requirements
15 A1.6 Introduction to Digital Camera Opacity Technique (DCOT)
A1.7 Equipment to Determine Plume Opacity in the Field Using Digital Camera Opacity Technique
16 A1.8 Documentation Needed to Determine Plume Opacity with DCOT
18 A1.9 Certification of DCOT
19 A1.10 Knowledgeable Users
20 A2.1
A3. QUALIFICATIONS AND TESTING
A3.1 Smoke Generator Specifications
TABLE A2.1
21 TABLE A3.1