ASTM-D5881:2005 Edition
$40.63
D5881-95(2005) Standard Test Method for (Analytical Procedure) Determining Transmissivity of Confined Nonleaky Aquifers by Critically Damped Well Response to Instantaneous Change in Head (Slug)
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 9 |
ASTM D5881-95-Reapproved2005
Historical Standard: Standard Test Method for (Analytical Procedure) Determining Transmissivity of Confined Nonleaky Aquifers by Critically Damped Well Response to Instantaneous Change in Head (Slug)
ASTM D5881
Scope
1.1 This test method covers determination of transmissivity from the measurement of water-level response to a sudden change of water level in a well-aquifer system characterized as being critically damped or in the transition range from underdamped to overdamped. Underdamped response is characterized by oscillatory changes in water level; overdamped response is characterized by return of the water level to the initial static level in an approximately exponential manner. Overdamped response is covered in Guide D4043; underdamped response is covered in D5785, D4043.
1.2 The analytical procedure in this test method is used in conjunction with Guide D4043 and the field procedure in Test Method D4044 for collection of test data.
1.3 LimitationsāSlug tests are considered to provide an estimate of the transmissivity of an aquifer near the well screen. The method is applicable for systems in which the damping parameter, Ī¶, is within the range from 0.2 through 5.0. The assumptions of the method prescribe a fully penetrating well (a well open through the full thickness of the aquifer) in a confined, nonleaky aquifer.
1.4 The values stated in SI units are to be regarded as standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
Aquifers; Barometric measurement; Confined aquifers; Environmental site assessment (ESA)–soil/rock; Ground water; Hydraulic conductivity/transmissivity; Observation wells; Overdamped well-aquifer system; Pumping rate; Slug tests; Storage–aquifers; Transmissivity; Underdamped well-aquifer system; Water level observation
ICS Code
ICS Number Code 07.060 (Geology. Meteorology. Hydrology)
DOI: 10.1520/D5881-95R05
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Summary of Test Method Solution |
3 | FIG. 1 FIG. 2 |
4 | Significance and Use Procedure Calculation and Interpretation of Results TABLE 1 |
5 | TABLE 2 TABLE 3 |
6 | Report TABLE 4 TABLE 5 |
7 | Precision and Bias Keywords TABLE 6 TABLE 7 |
8 | TABLE 8 TABLE 9 |
9 | REFERENCES TABLE 10 |