ASTM-D4923 2001
$40.63
D4923-01 Standard Specification for Reinforced Thermosetting Plastic Poles (Withdrawn 2010)
Published By | Publication Date | Number of Pages |
ASTM | 2001 | 10 |
ASTM D4923-01
Withdrawn Standard: Standard Specification for Reinforced Thermosetting Plastic Poles (Withdrawn 2010)
ASTM D4923
Scope
1.1 This specification covers reinforced thermosetting plastic poles used for outdoor lighting. Such poles may be applicable to electric power and telecommunication distribution installations.
1.2 The design parameters of the poles shall be agreed upon by the purchaser and supplier and should take into consideration the anticipated service conditions of installation and transportation of the product.
1.3 This specification includes poles with above-ground or standard mounting height of 10 ft (3.05 m) through 50 ft (15.24 m). Two classes of poles are covered, one of standard design, the other of stiff design.
1.4 The values stated in inch-pound units are to be regarded as standard. Equivalent SI units are indicated in parentheses.
1.5 The following precautionary caveat pertains only to the test methods portion of this specification, Section 10: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
reinforced thermosetting plastic poles; outdoor lighting; electric power; telecommunication distribution installations; installation; above ground; standard mounting
ICS Code
ICS Number Code 83.120 (Reinforced plast)
DOI: 10.1520/D4923-01
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Classes Ordering Information Materials and Manufacture Requirements Performance Requirements |
3 | Workmanship, Finish, and Appearance Wiring and Access FIG. 1 |
4 | Anchor Bolt Recommendations Dimensions, Weight, and Permissible Variations Breakaway Poles FIG. 2 |
5 | Test Methods FIG. 3 FIG. 4 FIG. 5 |
6 | FIG. 6 FIG. 7 |
7 | FIG. 8 FIG. 9 |
8 | Inspection Certification Product Identification Packaging and Package Marking X1. EQUATIONS FOR MAXIMUM BENDING MOMENT CAUSED BY WIND LOAD X1.1 |
9 | X1.7 X1.8 X2. APPLICATION OF WIND LOAD X2.1 X3. PROCEDURE FOR DETERMINING POLE TOP DEFLECTION X3.1 X3.2 X4. TORSIONAL MOMENT X4.1 X4.2 X4.3 FIG. X4.1 |
10 | X5. CENTROID OF LOADING-ARM AND LUMINAIRE COMBINED FIG. X5.1 |