Scope
1.1 These test methods cover procedures for the testing of varnished cotton fabrics and varnished cotton fabric tapes (Note 0) to be used as electrical insulation and are directly applicable to both “straight-cut” and “bias-cut” materials, unless otherwise stated in the test method. Note 1āMethods of testing varnished glass fabrics and tapes are given in Test Methods D 902.
1.2 The procedures appear in the following order:
1.3 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units may be approximate.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see , , , and .
Note 2
This standard resembles IEC 60394-2 in title only. The content is significantly different.
Keywords
breaking strength; dielectric breakdown voltage; dissipation factor; permittivity; tear resistance (internal); thread count; varnished cotton fabric; volume resistance
ICS Code
ICS Number Code 29.035.99 (Other insulating materials)
DOI: 10.1520/D0295-99R04
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Selection of Test Specimens Conditioning Significance and Use Test Specimens Procedure Report Precision and Bias Significance and Use Procedure |
3 | Report Precision and Bias Terminology Significance and Use Procedure Report Precision and Bias Significance and Use Apparatus Test Specimens Number of Specimens Conditioning Procedure Report |
4 | Precision and Bias Significance and Use Apparatus Test Specimens Conditioning Procedure Report Precision and Bias Significance and Use Apparatus Test Specimens Conditioning |
5 | Procedure Calculation Report Precision and Bias Significance and Use Short-Time, Step-by-Step, and Slow-Rate-of-Rise Tests FIG. 1 |
6 | Long-Time Tests Precision and Bias Significance and Use |
7 | Apparatus Test Specimens Conditioning Procedure Report Precision and Bias Significance and Use Electrodes Test Specimens |
8 | Conditioning Procedure Report Precision and Bias Significance and Use Electrodes Test Specimens Conditioning Procedure |
9 | Report Precision and Bias Significance and Use Test Specimens Procedure Dielectric Breakdown Voltage Report Precision and Bias Keywords |
10 | X1. APPARATUS FOR MAKING DIELECTRIC BREAKDOWN VOLTAGE TESTS ON INSULATING TAPE X1.1 Single-Shot Tester X1.2 Multiple-Electrode Tester |
11 | FIG. X1.1 |