ASME A112.18.6/CSA B125.6 – 2017(R2021) Flexible Water Connectors
Published By | Publication Date | Number of Pages |
ASME | 2017 | 31 |
This Standard establishes requirements for flexible water connectors used in potable water systems under continuous pressure and in accessible locations only. It covers physical and performance requirements, test methods, materials, connections, and other significant properties, in addition to a general description of materials used. Certain features of construction of the finished product are given, together with the method of marking and identification. The provisions of this Standard are not intended to prevent the use of any alternate material or method of construction provided any such alternate meets the intent of this Standard. This Standard is identical to CSA B125.6-09, Flexible Water Connections. This joint Standard was developed in response to an industry request for a Standard for testing flexible water connections that would be acceptable in both Canada and the United States.
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | ASME A112 Standards Committee on Plumbing Materials and Equipment |
12 | CSA Technical Committee on Plumbing Fittings |
17 | CSA/ASME Harmonization Task Group on Plumbing Fixtures |
19 | Preface |
21 | 1 Scope 2 Reference publications |
23 | 3 Definitions and abreviations 3.1 Definitions 3.2 Abbreviations 4 General requirements 4.1 Toxicity and lead content 4.2 Materials |
24 | 4.3 Coatings 4.4 Connections 4.4.1 General 4.4.2 Pipe threads 4.4.3 Hose end threads 4.4.4 Fill valve threads 4.4.5 Solder connections 4.4.6 Flare connections 4.4.7 Compression connections |
25 | 4.4.8 Push-fit fittings 4.4.9 Alternate connections 4.5 Water heater flexible connectors 4.6 Working pressure 4.7 Working temperature 5 Performance requirements and test methods 5.1 General 5.2 Intermittent impulse pressure test 5.2.1 Performance |
26 | 5.2.2 Procedure 5.3 Burst pressure test 5.3.1 Performance 5.3.2 Procedure 5.4 Pressure drop test 5.4.1 Performance 5.4.2 Set-up |
27 | 5.4.3 Procedure 5.5 Torque test 6 Markings |
29 | Annex A (informative)Exposure to aqueous chloramine |
30 | Annex B (informative)Unit conversion and rounding criteria |