ANSI/AAMI/IEC 60601-2-4:2010/A1:2018 (Consolidated Text) – Medical electrical equipment-Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators, including Amendment 1
Published By | Publication Date | Number of Pages |
AAMI | 2010 | 82 |
This consolidated version includes the amendment which updates references and clarifies the scope as well as provides additional information for AEDs, defibrillator electrodes, audible warnings and cables.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ANSI/AAMI/IEC 60601-2-4:2010/A1:2018; Medical electrical equipment—Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators, including Amendment 1 (Consolidated Text) |
3 | Title page |
4 | AAMI Standard AAMI Standard Copyright information |
5 | Contents |
7 | Committee representation |
8 | Background of ANSI/AAMI adoption of IEC 60601-2-4:2010/A1:2018 |
9 | Foreword |
13 | 201.1 Scope, object and related standards 201.1. 1 * Scope |
14 | 201.1. 2 Object 201.1. 3 Collateral standards 201.1. 4 Particular standards |
15 | 201.2 Normative references 201.3 Terms and definitions |
18 | 201.4 General requirements 201.4. 2 Risk management process for me equipment or me systems 201.4. 2.101 * Additional risk management requirements 201.4. 3 Essential performance 201.4. 3.101 * Additional essential performance requirements Table 201.101 – Distributed ESSENTIAL PERFORMANCE requirements 201.5 General requirements for testing of me equipment 201.5.3 * Ambient temperature, humidity, atmospheric pressure |
19 | 201.5.4 Other conditions 201.5.8 Sequence of tests 201.6 Classification of me equipment and me systems 201.6.2 * Protection against electric shock 201.7 Me equipment identification, marking and documents 201.7.2 Marking on the outside of me equipment or me equipment parts 201.7.2.7 * Electrical input power from the supply mains 201.7.2.101 * Concise operating instructions |
20 | 201.7.2.102 * Internally powered me equipment 201.7.2.103 Disposable defibrillator electrodes 201.7.4 Marking of controls and instruments 201.7.4.101 * Selected energy control 201.7.9.2.4 * Electrical power source |
21 | 201.7.9.2.101 * Supplementary instructions for use |
22 | 201.7.9.3 Technical description 201.7.9.3.101 * Essential performance data for defibrillation 201.7.9.3.102 * Essential performance data of any synchronizer |
23 | 201.7.9.3.103 * Essential performance data of the rhythm recognition detector 201.8 Protection against electrical hazards from me equipment 201.8.3 * Classification of applied parts 201.8.5.5.1 * Defibrillation protection |
24 | 201.8.5.5.101 * Isolation of defibrillator electrodes |
25 | Figure 201.101 – Dynamic test for limitation of energy from different parts of the ME EQUIPMENT 201.8.5.5.102 * Applied parts not being defibrillator electrodes 201.8.5.5.103 Charging of the energy storage device 201.8.7 * Leakage currents and patient auxiliary currents 201.8.7.1 * General requirements |
26 | 201.8.7.3 * Allowable values 201.8.7.4.7 Measurement of the patient leakage current 201.8.8.3 * Dielectric strength |
29 | Figure 201.102 – Allowed current versus applied test voltage 201.8.9.1 Values 201.8.9.1.5 * me equipment rated for high altitudes 201.8.9.1.101 * defibrillator electrodes, high-voltage circuits and cables |
30 | 201.9 Protection against mecahnical hazards of me equipment and me systems 201.10 Protection against unwanted and excessive radiation hazards 201.11 Protection against excessive temperatures and other hazards 201.11.1.3 Measurements |
31 | 201.11.6.3 * Spillage on me equipment and me systems 201.11.6.5 Ingress of water or particulate matter into me equipment and me systems |
32 | 201.11.6.7 * Sterilization of me equipment and me systems 201.12 * Accuracy of controls and instruments and protection against hazardous outputs 201.12.1 * Accuracy of controls and instruments 201.12.2 Usability 201.12.2.101 * ELECTRODE energizing controls |
33 | 201.12.2.102 Display of signals 201.12.4 Protection against hazardous output 201.12.4.1 * Intentional exceeding of safety limits 201.12.4.101 * Output voltage 201.12.4.102 * Unintentional energy 201.12.4.103 * Internal discharge circuit |
34 | 201.13 Hazardous situations and fault conditions 201.13.1.3 * Exceeding leakage current or voltage limits 201.14 Programmable electrical medical systems (pems) 201.15 Construction of me equipment 201.15.4 * Me equipment components and general assembly 201.15.4.3 Batteries 201.15.4.3.101 * Battery replacement 201.15.4.3.102 Battery charging indicator 201.15.4.3.103 * Rechargeable battery |
35 | 201.15.4.101 * Defibrillator electrodes and their cables |
37 | Figure 201.103 – Examples of cord anchorages that require testing |
38 | Figure 201.104 – Test apparatus for flexible cords and their anchorages 201.16 Me systems 201.17 Electromagnetic compatibility of me equipment and me systems 201.101 * Charging time 201.101.1 Requirements for frequent use, manual defibrillators |
39 | 201.101.2 Requirements for infrequent use, manual defibrillators |
40 | 201.101.3 * Requirements for frequent use, automated external defibrillators 201.101.4 * Requirements for infrequent use, automated external defibrillators |
41 | 201.102 Internal electrical power source 201.102.1 General 201.102.2 * Requirements for manual defibrillators 201.102.3 * Requirements for automated external defibrillators (AED) 201.102.3.1 Frequent use AED |
42 | 201.102.3.2 Infrequent use AED |
43 | 201.103 * Endurance 201.104 * Synchronizer |
44 | 201.105 * Recovery of the monitor and/or ECG input after defibrillation 201.105.1 ECG signal derived via defibrillator electrodes |
45 | Figure 201.105 – Arrangement for test of recovery after defibrillation 201.105.2 ECG signal derived via any separate monitoring electrodes |
46 | Figure 201.106 – Arrangement of monitoring electrodes on sponge Figure 201.107 – Arrangement for recovery test after defibrillation 201.105.3 ECG signal derived via non-reusable defibrillator electrodes |
47 | 201.106 * Disturbance to the monitor from charging or internal discharging |
48 | Figure 201.108 – Arrangement for test of disturbance from charging and internal discharging 201.107 * Requirements for rhythm recognition detector |
49 | Table 201.102 – RHYTHM RECOGNITION DETECTOR categories 201.108 Defibrillator electrodes 201.108.1 * Defibrillator electrodes for monitoring and defibrillation, and (optionally) pacing 201.108.1.1 * AC small signal impedance 201.108.1.2 * AC large signal impedance |
50 | 201.108.1.4 * Defibrillation recovery 201.108.1.5 * Biological response 201.108.1.6 * DC offset voltage 201.108.1.7 * Electrode active area 201.108.1.8 * Electrode adhesion and contact to patient 201.108.1.9 * Packaging and shelf life |
51 | 201.108.1.10 * Universal-function electrodes 201.108.1.11 * Cable length 201.109 * External pacing 201.109.1 Pacing mode activation 201.109.2 Pacing delivery 201.109.2.1 Separate pacing pathway |
52 | 201.109.2.2 Combined pathway 201.109.3.1 Pace pulse duration accuracy 201.109.3.2 Pace pulse duration stability |
53 | 201.109.4 Pacing pulse current 201.109.4.1 Pacing pulse current accuracy 201.109.4.2 Pacing pulse current stability 201.109.5 Pacing rate 201.109.5.1 Pacing rate accuracy 201.109.5.2 Pacing rate stability |
54 | 201.109.6 Pacing protocol 201.109.7 Demand pacing 201.109.8 Pacer lead-off indication |
55 | Figure 201.110 – Test circuit for DEFIBRILLATOR overload test of pacing output circuitry 202 * Electromagnetic compatibility – Requirements and tests 202.6.1 Emissions 202.6.1.1 Protection of radio services 202.6.1.1.1 Requirements 202.6.2.2 Electrostatic discharge (ESD) |
56 | 202.6.2.2.1 Requirements 202.6.2.2.2 Tests 202.6.2.3 Radiated RF electromagnetic fields 202.6.2.3.1 Requirements 202.6.2.3.2 * Tests 202.6.2.4 Electrical fast transients and bursts 202.6.2.4.1 Requirements |
57 | 202.6.2.4.2 Tests 202.6.2.5 Surges 202.6.2.5.1 Requirements 202.6.2.6 Conducted disturbances, induced by RF fields 202.6.2.6.1 Requirements 202.6.2.6.2 Tests 202.6.2.8.1 Power frequency magnetic fields 202.6.2.8.1.1 Requirements 202.6.2.8.1.2 Test |
58 | Annexes |
59 | Annex C (informative) Guide to marking and labelling requirements for me equipment and me systems 201.C.1 Marking on the outside of me equipment, me systems or their parts Table 201.C.101 – Marking on the outside of a CARDIAC DEFIBRILLATOR or its parts 201.C.3 Marking of controls and instruments 201.C.4 Accompanying documents, general |
60 | Table 201.C.102 – Marking of controls and instruments of a CARDIAC DEFIBRILLATOR Table 201.C.103 – ACCOMPANYING DOCUMENTS, general 201.C.5 Accompanying documents, Instructions for use Table 201.C.104 – ACCOMPANYING DOCUMENTS, instructions for use 201.C.6 Accompanying documents, technical description Table 201.C.105 – ACCOMPANYING DOCUMENTS, technical description |
61 | Annex AA (informative) Particular guidance and rationale AA.1 General guidance AA.2 Rationale for particular clauses and subclauses |
74 | Figure AA.1 – Simulated PATIENT load |
75 | Annex BB (informative) Mapping between the elements of the second edition of IEC 60601-2-4 and IEC 60601-2-4:2010 Table BB.1 – Mapping between the elements of the second edition of IEC 60601-2-4 and IEC 60601-2-4:2010 |
80 | Bibliography |
81 | Index of defined terms used in this particular standard |