{"id":82413,"date":"2024-10-18T03:04:59","date_gmt":"2024-10-18T03:04:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-433-1974\/"},"modified":"2024-10-24T19:50:05","modified_gmt":"2024-10-24T19:50:05","slug":"ieee-433-1974","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-433-1974\/","title":{"rendered":"IEEE 433 1974"},"content":{"rendered":"
New IEEE Standard – Inactive – Withdrawn. Withdrawn Standard. Withdrawn Date: Jan 16, 2004. Abstract: Terms that have a specific meaning in VLF testing are defined, and VLF test equipment and wave shape are described. A uniform procedure for testing the armature insulation of large AC machines with VLF voltage is provided. Constants for relating VLF tests to power-frequency and direct-voltage tests to obtain equally effective test levels are recommended.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Introduction Participants <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | 1. Scope and Purpose <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 2. Definitions 3. Preparations for Test 3.1 Air-Cooled Machines <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 3.2 Hydrogen-Cooled Machines 3.3 Liquid-Cooled Armataure Windings 3.4 Isolation of the Winding from Cables and Auxiliary Equipment 3.5 Sectionalizing and Winding 4. Safety Considerations 4.1 Area Isolation <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4.2 Grounding Precautions 4.3 Grounding Provisions 4.4 Safety Checklist 5. General Test Considerations 5.1 Possibility of Failure to Pass Test 5.2 Condition of Winding <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 5.3 Test-Voltage Determination 6. Test Equipment 6.1 Equipment Specifications 6.2 Instrumentation 6.3 Protection of Equipment and Test Specimen 6.4 Power Source to the VLF-Test Equipment 6.5 Operation Check <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 7. Test Connections 7.1 Ground Connections 7.2 High-Voltage-Test Connections 8. Test Procedure 8.1 Voltage Application <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 8.2 Fault Detection 9. Test Results 9.1 Interpretation 9.2 Suggested Test Record 9.3 Comments to Be Recorded <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 10. Standards References 11. Bibliography <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Annex A\u2014General Principles of High-Voltage Testing <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Voltage at Very Low Frequency<\/b><\/p>\n |