{"id":374662,"date":"2024-10-20T02:39:43","date_gmt":"2024-10-20T02:39:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-ts-16733-22021\/"},"modified":"2024-10-26T04:38:22","modified_gmt":"2024-10-26T04:38:22","slug":"bsi-pd-iso-ts-16733-22021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-ts-16733-22021\/","title":{"rendered":"BSI PD ISO\/TS 16733-2:2021"},"content":{"rendered":"

This document provides guidance for the specification of design fires for use in fire safety engineering analysis of building and structures in the built environment. The design fire is intended to be used in an engineering analysis to determine consequences in fire safety engineering (FSE) analyses.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
7<\/td>\nForeword <\/td>\n<\/tr>\n
8<\/td>\nIntroduction <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
11<\/td>\n4 Symbols <\/td>\n<\/tr>\n
14<\/td>\n5 The role of design fires in fire safety design <\/td>\n<\/tr>\n
18<\/td>\n6 Considerations based on methods of analysis
7 Elements of a design fire
7.1 General <\/td>\n<\/tr>\n
20<\/td>\n7.2 Incipient stage
7.3 Growth stage <\/td>\n<\/tr>\n
21<\/td>\n7.4 Flashover
7.5 Fully developed stage <\/td>\n<\/tr>\n
22<\/td>\n7.6 Events that change a design fire
7.6.1 General
7.6.2 Suppression systems
7.6.3 Intervention by fire services <\/td>\n<\/tr>\n
23<\/td>\n7.6.4 Changes in ventilation
7.6.5 Enclosure effects
7.6.6 Combustible construction materials
7.7 Extinction and decay stage <\/td>\n<\/tr>\n
24<\/td>\n8 Constructing a design fire curve
8.1 Procedure <\/td>\n<\/tr>\n
25<\/td>\n8.2 Step 1 \u2014 Parameters provided by the design fire scenario <\/td>\n<\/tr>\n
26<\/td>\n8.3 Step 2 \u2014 Fires involving single or multiple fuels
8.3.1 General <\/td>\n<\/tr>\n
27<\/td>\n8.3.2 Develop the design fire curve for first item
8.3.3 Ignition of other items <\/td>\n<\/tr>\n
28<\/td>\n8.3.4 Power law design fire curves <\/td>\n<\/tr>\n
29<\/td>\n8.3.5 Wall and ceiling linings
8.3.6 Smouldering fires <\/td>\n<\/tr>\n
30<\/td>\n8.4 Step 3 \u2014 Flashover
8.4.1 General
8.4.2 Empirical correlations for critical heat release rate for onset of flashover <\/td>\n<\/tr>\n
31<\/td>\n8.5 Step 4 \u2014 Maximum heat release rate
8.5.1 General
8.5.2 Fuel-controlled fires <\/td>\n<\/tr>\n
32<\/td>\n8.5.3 Ventilation-controlled fires <\/td>\n<\/tr>\n
33<\/td>\n8.5.4 Mechanical ventilation
8.6 Step 5 \u2014 Modifying the design fire curve
8.6.1 Suppression systems <\/td>\n<\/tr>\n
34<\/td>\n8.6.2 Fire service intervention
8.6.3 Changes in ventilation
8.6.4 Enclosure effects on mass loss rate of fuel <\/td>\n<\/tr>\n
35<\/td>\n8.7 Step 6 \u2014 Fire duration
8.7.1 Duration of the fire growth stage
8.7.2 Duration of the steady burning stage <\/td>\n<\/tr>\n
36<\/td>\n8.8 Step 7 \u2014 Decay
9 Species production
9.1 Species yields
10 Design fires for structural fire engineering
10.1 General <\/td>\n<\/tr>\n
37<\/td>\n10.2 Localized fires
10.2.1 Flames not impinging the ceiling <\/td>\n<\/tr>\n
38<\/td>\n10.2.2 Flames impinging the ceiling <\/td>\n<\/tr>\n
39<\/td>\n10.3 Parametric fires <\/td>\n<\/tr>\n
40<\/td>\n10.3.1 Heating phase <\/td>\n<\/tr>\n
41<\/td>\n10.3.2 Heating duration and maximum temperature <\/td>\n<\/tr>\n
42<\/td>\n10.3.3 Cooling phase
10.4 Fires in large compartments (travelling fires) <\/td>\n<\/tr>\n
45<\/td>\n11 External design fires <\/td>\n<\/tr>\n
46<\/td>\n12 Fire tests
13 Probabilistic aspects of design fires
13.1 General <\/td>\n<\/tr>\n
47<\/td>\n13.2 Inclusion of statistical representativeness\/distribution characteristics
13.3 Simulations using distributed input and sampling techniques <\/td>\n<\/tr>\n
48<\/td>\n13.4 Stochastic models <\/td>\n<\/tr>\n
49<\/td>\n13.5 Results of probabilistic analysis and their evaluation <\/td>\n<\/tr>\n
50<\/td>\n14 Documentation <\/td>\n<\/tr>\n
51<\/td>\nAnnex A (informative) Data for development of design fires <\/td>\n<\/tr>\n
57<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Fire safety engineering. Selection of design fire scenarios and design fires – Design fires<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2021<\/td>\n62<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":374670,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[236,2641],"product_tag":[],"class_list":{"0":"post-374662","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-01","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/374662","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/374670"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=374662"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=374662"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=374662"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}